Chapter 6: Minimum To Post And System Management Configuration Validation; Minimum Configuration To Post; Configuration Validation - Dell PowerEdge XE8640 Installation And Service Manual

Table of Contents

Advertisement

Minimum to POST and system management
This section describes the minimum to POST system requirement and system management configuration validation of the Dell
system.
Topics:

Minimum configuration to POST

Configuration validation

Minimum configuration to POST
The components mentioned below are the minimum configuration to POST:
● Power button control panel and cable
● Power Distribution Board(PDB) and cables
● PCIe Switch Board(PSB) and cables
● Two processors in processor socket 1 and 2
● Two memory modules(DIMMs) in slot A1 and B1
● System Board+RIO Card
● One 2800W PSU(54V) and 54V PSU power cord
Configuration validation
The new generation of Dell systems have added interconnect flexibility and advanced iDRAC management features to collect
precise system configuration information and report configuration errors.
When the system is powered on, information about installed cables, risers, backplanes, power supplies, floating card
(fPERCadapter PERC , BOSS), and processor is obtained from the CPLD and backplane memory maps are analyzed. This
information forms a unique configuration, which is compared with one of the qualified configurations that are stored in a table
maintained by iDRAC.
One or more sensors are assigned to each of the configuration elements. During POST, any configuration validation error is
logged in the System Event Log (SEL)/LifeCycle (LC) log. The reported events are categorized in the configuration validation
error table.
Table 55. Configuration validation error
Error
Description
Config Error
A configuration element within the
closest match contains something that is
unexpected and does not match any Dell
qualified configuration.
Config
iDRAC found a configuration element
Missing
missing within the closest match
detected.
configuration validation
Possible cause and
recommendations
Wrong configuration
The element reported
in HWC8010 errors are
assembled incorrectly.
Verify element (cable,
risers, etc) placement in
the system.
Missing or damaged cable,
device, or part
Minimum to POST and system management configuration validation
Example
Config Error: Backplane cable
CTRS_SRC_SA1 and BP-DST_SA1
Config Error : SL Cable
PLANAR_SL7 and CTRL_DST_PA1
Config Missing: Float card front
PERC/HBAadapter PERC/HBA
6
55

Advertisement

Table of Contents
loading

This manual is also suitable for:

E91s

Table of Contents