Cleaning And Sanitizing - Follett D17617 Installation, Operation And Service Manual

Countertop and freestanding ice and water dispenser with chewblet ice icemaker
Table of Contents

Advertisement

Cleaning and Sanitizing –––––––––––––––––––––––––––––––––––––––––––––
Cleaning and sanitizing should be performed at least every 6 months, and
more often if local water conditions dictate .
CAUTION!
Place the dispenser in Maintenance Mode prior to servicing or
cleaning the ice machine. See
page
11.
Required Supplies
§ (3) x 7 ounce SafeCLEAN™ environmentally-friendly icemaker cleaner
packets
§ Nu-Calgon IMS-II sanitizing concentrate
§ Funnel
§ Bucket
Cleaning: Icemaker and Dispenser
1 . Dispense all the ice out of the unit, then see
2 . Press and hold maintenance/clean switch until
Mode .
3 . Remove (unscrew) chrome ice dispense chute .
4 . Remove drip tray .
5 . Remove (2) screws located behind the drip tray .
6 . Move front panel and place on top or beside unit .
7 .
Remove plug cap from the end of drain tube and lower tube to drain water into bucket .
8 . After the system has been drained of water replace plug cap in drain tube .
9 . Secure tube in holder .
10 . Remove cap from bin lid cover .
11 . Screw cap onto ice discharge chute .
12 . Mix SafeCLEAN Ice Machine Cleaner, (3) x 7 ounce packets, with three gallons (11 .4 L) of water .
13 . Pour cleaning solution into bin lid access spout until solution reaches the spout neck .
14 . Allow the solution to remain in unit for 15 minutes .
15 . While machine is cleaning, remove top and right side panel to access and clean air-cooled condenser .
16 . Drain system by lowering drain tube into bucket .
17 . Secure drain tube into holder .
18 . Fill one time with potable water and drain with fill tube . Secure drain tube .
Sanitizing: Icemaker and Dispenser
1 . Mix a sanitizing solution of 2 .5 gallons (9 .5 L) of water and 4 ounces (118 ml) of Nu-Calgon IMS-II
sanitizing concentrate .
2 . Pour sanitizing solution into bin lid access spout until solution reaches the spout neck .
3 . Allow the solution to remain in unit for 5 minutes .
4 . Drain system by lowering drain tube .
5 . Secure drain tube into holder .
6 . Fill and drain three times with potable water .
7 .
Place a bucket under the dispense chute and remove cap .
Caution: Some sanitizing solution will remain and drain out when cap is removed . Reposition cap on bin lid spout .
8 . Reinstall front panel, ice dispense chute, and drip tray .
9 . Press and hold maintenance/clean switch to exit Maintenance Mode .
Maintenance/Cleaning Mode on
Accessing Internal Components on page
displays in the user interface to enter Maintenance
Fig . 16
1
Dispenser and Icemaker 7CI100A/7FS100A
11.
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

7fs100a7ci100aD25455

Table of Contents