3 .Specifications - Yoshitake GD-46 Series Instruction Manual

Home water pressure reducing valve
Table of Contents

Advertisement

3 .Specifications
Nominal diameter
Application
Inlet pressure
Reduced pressure
Minimum differential
pressure
Maximum pressure
reduction ratio
Working
temperature
Min. adjustable flow rate
Rated flow
Pressure check function
● Pressure gauges (type A and D) are option. (0.5 MPa)
Pressure gauge (JIS R1/8) is to be connected at the site.
Accuracy of the pressure gauge is ±3% F.S.
● Strainer has a mesh size of 60.
● Factory setting is reducing valve function.
● An incombustible material is used for heat insulating material.
CAUTION
Please confirm that the indications on the product correspond with the specifications of the
ordered product model before use.
* If they are different, please contact us without using the product.
(A)
(B)
(C)
w/o pipe end core
w/ pipe end core
w/ check valve
50 L/ min (Pressure difference between upstream and
w/o check valve
30 L/ min (Pressure difference between upstream and
w/ check valve
20A
City water
1.0 MPa or less
0.05~0.10MPa
(Standard setting: 0.09MPa )
0.10~0.22MPa
(Standard setting: 0.20MPa )
0.20~0.30MPa
(Standard setting: 0.25MPa )
0.02MPa
10:1
5~90℃
5~40℃
5~60℃
0.5 L/min
downstream of the valve:0.10 MPa or more)
downstream of the valve:0.10 MPa or more)
Pressure gauge joint (JIS Rc1/8)
-2-