Baumatic BHG300.6SS Instruction Manual page 10

Table of Contents

Advertisement

Always disconnect the appliance from the
electricity main before making any adjustments.
All seals must be replaced by the technician at
the end of any adjustments or regulations.
Our burners do not require primary air
adjustment.
9) TAPS
"Reduced rate" adjustment
- Switch on the burner and turn the relative knob to
the "Reduced rate" position (small flame fig. 1).
- Remove knob "M" (fig. 12 and 12/A) of the tap,
which is simply pressed on to its rod. The by-pass
for minimal rate regulation can be: beside the tap
(fig. 12) or inside the shaft. In any case, to access
to regulation, it can be done through the insertion
of a small screwdriver ''D'' beside the tap (fig. 12)
or in the hole ''C'' inside the shaft of the tap
(fig 12/A). Turn the throttle screw to the right or left
until the burner flame has been adequately
regulated to the "Reduced rate" position.
The flame should not be too low: the lowest small
flame should be continuous and steady. Re-
assemble the several components.
ADJUSTMENTS
FIG. 12
It is understood that only burners operating
with G20 gas should be subjected to the above
mentioned adjustments. The screw must be
fully locked when the burners operate with G30
or G31 gas (turn clockwise).
9
FIG. 12/A

Advertisement

Table of Contents
loading

Table of Contents