Baumatic BHG900.6SS Instruction Manual

90 cm 5 burner gas hob

Advertisement

Quick Links

BHG900.6SS
-
90 cm 5 Burner Gas Hob
INSTRUCTION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Baumatic BHG900.6SS

  • Page 1 BHG900.6SS 90 cm 5 Burner Gas Hob INSTRUCTION MANUAL...
  • Page 2 The manufacturer shall not be held responsible for any damages to persons or property caused by incorrect installation or use of the appliance. MODEL: BHG900.6SS The Manufacturer shall not be held responsible for any inaccuracies in this handbook due to printing or transcription errors;...
  • Page 3 DESCRIPTION OF THE GAS HOBS MOD: MOD: MOD: BHG900.6SS MOD: 1 Ultra rapid burner of 3100 W 2 Rapid burner of 2800 W 3 Semirapid gas burner of 1750 W 4 Auxiliary gas burner of 1000 W 5 Pan stand support right...
  • Page 4 1) BURNERS Power Pan Ø Burners A diagram is printed above each knob on the ratings in cm front panel. This diagram indicates to which Ultra rapid 3100 24 ÷ 26 burner the knob in question corresponds. After Rapid 2800 20 ÷...
  • Page 5 WARNINGS AND ADVICE FOR THE USER: Use of a gas cooking appliance produces heat and moisture in the room in which it is installed. The room must therefore be well ventilated by keeping the natural air vents clear (fig. 3) and by activating the mechanical aeration device (extraction hood or electric fan fig.
  • Page 6 CLEANING IMPORTANT: WARNINGS: Comply with the following instructions, before Always disconnect the appliance from the gas remounting the parts: and electricity mains before carrying out any - Check that burner head slots “T” (fig. 6) have cleaning operation. not become clogged by foreign bodies. 2) GAS HOB - Check that enamelled burner cap “C”(fig.
  • Page 7: Installation

    INSTALLATION TECHNICAL INFORMATION FOR THE 4) FIXING THE HOB INSTALLER The hob has a special seal which prevents liquid Installation, adjustments of controls and from getting into the cabinet. Strictly comply with maintenance must only be carried out by a the following instructions in order to correctly qualified engineer.
  • Page 8: Gas Pressure Test

    INSTALLATION I M P O RTA N T I N S TA L L AT I O N 7) GAS CONNECTION Before connecting the appliance, check S P E C I F I C AT I O N S that the values on the data label affixed to The rear wall and the surfaces surrounding the underside of the hot plate correspond and adjacent to the appliance must be able to...
  • Page 9: Electrical Connection

    INSTALLATION 8) ELECTRICAL CONNECTION - Remember that the earth wire must not be interrupted by the circuit-breaker. - The electrical connection may also be protected IMPORTANT: the appliance must be installed following the manufacturer's by a high sensitivity differential circuit- breaker. instructions.
  • Page 10 ADJUSTMENTS Always disconnect the appliance from the It is understood that only burners operating electricity main before making any adjustments. with G20 gas should be subjected to the above All seals must be replaced by the technician at mentioned adjustments. The screw must be the end of any adjustments or regulations.
  • Page 11: Replacing The Injectors

    CONVERSIONS 10) REPLACING THE INJECTORS paragraphs 9. The technician must reset any seals on the regulating or pre-regulating devices. The burners can be adapted to different types of The envelope with the injectors and the labels can gas by mounting injectors suited to the type of gas be included in the kit, or at disposal to the in question.
  • Page 12 SERVICING Always disconnect the appliance from the Greasing the taps (see fig. 18 - 19) electricity and gas mains before proceeding If a tap becomes stiff to operate, it must be with any servicing operation. immediately greased in compliance with the following instructions: - Remove the tap.
  • Page 13 SERVICING CABLE TYPES AND SECTIONS TYPE OF SINGLE - PHASE TYPE OF HHOB Gas CABLE POWER SUPPLY H05 RR - F Section 3 x 0.75 mm Gas Hob ATTENTION!!! If the power supply cable is replaced, the installer should leave the ground wire longer than the phase conductors (fig.
  • Page 14 Voltage = 220 - 240 V~ Voltage = 220 - 240 V~ Frequency = 50/60 Hz Frequency = 50/60 Hz 5 BURNERS (90) 4 BURNERS (2 UR) (90) BHG900.6SS CAT. = II2H3+ CAT. = II2H3+ G30- BUTANE = 28-30 mbar G30- BUTANE = 28-30 mbar...
  • Page 15 TECHNICAL DATA FOR THE APPLIANCE GAS REGULATION...
  • Page 16: Technical Assistance And Spare Parts

    TECHNICAL ASSISTANCE AND SPARE PARTS Before leaving the factory, this appliance will have been tested and regulated by expert and specialised personnel in order to guarantee the best performances. Any repairs or adjustments which may be subsequently required may only be carried out by qualified personnel with the utmost care and attention.
  • Page 19 Kundendienst & Ersatzteile (0118) 933 6933 Deutschland 0049(0)180-5888975 E-mail: Oesterreich +43 (0) 820 / 420423 sales@baumatic.co.uk customercare@baumatic.co.uk www.baumatic.de spares@baumatic.co.uk technical@baumatic.co.uk Italy Baumatic Italia S.R.L. Website: Via Galvani N.3 www.baumatic.co.uk 35011 Campodarsego (PD) Facebook: +3904 9920 2297 www.facebook.com/baumatic.uk www.baumatic.it Republic of Ireland Holland Baumatic Benelux B.V.
  • Page 20 www.baumatic.com...