Command and Response Table for SIS Commands
Command Name
Output scaler rate
Set output rate
View current output rate
X2$
KEY:
= Scaler resolution
Output aspect ratio
Set output aspect ratio
View current output aspect ratio
X2%
KEY:
= Aspect Ratio
Freeze
Set freeze
View current freeze setting
X3)
KEY:
= Enable or disable
Executive mode (front panel lockout)
Set executive mode
View current executive mode
setting
X3)
KEY:
= Enable or disable
Global unsolicited response
Output scaler rate
Output aspect ratio
Freeze
X2$
KEY:
= Scaler resolution
X2%
= Aspect Ratio
X3)
= Enable or disable
SIS Variable (
Resolution
23.98 Hz
1024x768
1280x800
1280x1024
1680x1050
1920x1200
720p
1080p
38
2048x1080
46
3840x2160
59
Scaler bypass mode
Custom output rate
*Default output resolution
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide
6
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876
SIS Command
E X2$
}
RATE
E
}
RATE
Verbose mode 2/3
0
3-digit response with
padding (See the Output Resolution table)
E X2%
}
ASPR
E
}
ASPR
Verbose mode 2/3
1
= Fill (default)
X3)
F
F
Verbose mode 2/3
0
= Disable (default)
X3)
X
X
Verbose mode 2/3
0
= Disable (default)
0
3-digit response with
padding (See the Output Resolution table)
1
= Fill (default)
0
= Disable (default)
X2$
) for Selected Output Reolution and Refresh Rate Combinations
24 Hz
25 Hz
29
39
40
47
48
60
61
on the Extron website.
© 2023 Extron — All rights reserved.
All trademarks mentioned are the property of their respective owners.
SIS Response
X2$]
Rate
X2$]
X2$]
Rate
X2%]
Aspr
X2%]
X2%]
Aspr
2
= Follow
X3)]
Frz
X3)]
X3)]
Frz
1
= Enable
X3)]
Exe
X3)]
X3)]
Exe
1
= Enable (front panel is locked)
X2$]
Rate
X2%]
Aspr
X3)]
Frz
2
= Follow
1
= Enable
29.97 Hz
30 Hz
30
31
41
42
49
50
62
63
199
The signal bypasses the scaler. The output clock follows the
input clock
201
Captured or uploaded EDID
www.extron.com
Additional Description
X2$
Set output rate to
.
X2%
Set output rate to
.
Enable freeze setting.
Enable executive mode setting.
When output rate is changed.
When aspect ratio is changed.
When freeze setting is changed.
50 Hz
59.94 Hz
32
33
43
44
51
52
64
65
60 Hz
12
14
15
21
23
34
45*
53
66
68-3130-50 Rev. A
05 23