FOX3 SR 301 and FOX3 SR 311 • Setup Guide (Continued)
d.
Connect peripheral devices to the USB ports (see figure 2) .
NOTES:
•
The FOX3 matrix switches the USB HID and USB 2.0 inputs and outputs independently of the video and each USB
connection.
•
The USB 2.0 port is only available on the FOX3 SR 301 device.
•
The USB HID ports are used only for a mouse or keyboard.
•
The USB 2.0 ports are used for thumb drives, cameras, keyboards, a mouse, CAC reader, and such devices.
L
Laptop
t
USB
~
100-240V
0.7A MAX
L
R
USB HID
AUDIO
L
R
50-60 Hz
Transmitter
Figure 3.
Peripheral USB Connections Diagram
•
USB Host ports (
•
USB Hub ports (
Step 3 — Control Connections
a.
To pass serial, IR data, or control signals, such as for serial control of a projector,
connect the master device to the transmitter and the controlled device to the
receiver via the CONTROL 5-pole captive screw connector (see figure 1,
page 1 and figure 4 for wiring).
NOTE:
For returned RS-232 and IR responses (from the scaling receiver to the
transmitter) install the receiver-Tx-to-transmitter-Rx fiber cable in
b.
For stereoscopic 3D sync such as an external IR emitter for glasses, connect a
display or projector to the two right poles of the REMOTE RS-232/3D Sync 5-pole
captive screw port (
c.
For remote control of a unit and loading firmware (LAN or USB only), connect a host device, such as a computer or control
system, to one of the following ports (see the FOX3 SR 301 and FOX3 SR 311 User Guide, available at www.extron.com, for
details):
Remote RS-232 port — Connect the 3 left poles of this 5-pole captive screw connector to this port (
•
The protocol for the Remote port is as follows:
•
9600 baud
•
1 stop bit
•
LAN Ethernet port — Connect an RJ-45 connector to this port (
•
USB Configuration port — Connect a USB mini-B connector to this port (see figure 6,
2
USB
INPUTS
RS-232
IR
HDMI
Tx Rx
G
Tx Rx
REMOTE
3D
USB 2.0
LAN
SYNC
RS-232
LOOP OUT
HOST
HOST
Tx Rx
G
S 5V
A A A
A
) — Connect a USB type A to B cable between this USB type B port and the USB port of a host.
B
) — Connect a USB type A cable between the USB type A port and peripherals.
G
).
•
no parity
•
no flow control
~
100-240V
0.7A MAX
OUTPUTS
A
B
R
OUT
IN
OUT
IN
50-60 Hz
Receiver
SM or MM cable
H
step
4b.
•
8 data bits
I
).
Keyboard
y
Mouse
USB
USB
OUTPUTS
L
R
RS-232
IR
DEVICES
Tx Rx
G
Tx Rx
USB HID
1
REMOTE
3D
AUDIO
SYNC
USB 2.0
L
R
RS-232
2
1
100 mA
500 mA
HDMI
Tx Rx
G
S 5V
B B B
USB
Thumb Drive
CONTROL
on
Figure 4.
RS-232 and IR Wiring
G
B
on page 3).
INPUTS
A
B
LAN
R
OUT
IN
OUT
IN
I R D evi ce
R x
Tx
Gnd
Tx
R x
Gnd
RS-232 D evi ce
).
Need help?
Do you have a question about the FOX3 SR 301 and is the answer not in the manual?
Questions and answers