Product Description

The A605 is designed to extend the AC current range of a multimeter
up to 500 amps by acting as a proportional current/voltage
transformer. It is compatible with multimeters having an AC volts
function with an input resistance 1 M .

General Safety Summary

Observe Maximum Working Voltage
Do not use the A605 above 440 VAC.
Do Not Operate in Wet/Damp Conditions
To avoid personal injury or damage to this product from electric
shock, do not operate this product in wet/damp conditions.
Do Not Operate in an Explosive Atmosphere
To avoid personal injury or fire hazard, do not operate this product in
an explosive atmosphere.
Do Not Immerse in Liquids
Clean the probe using a damp cloth. Refer to the cleaning instruc-
tions on page 6.
Do Not Use if Damaged
If you suspect that there is damage to this product, have it inspected
by qualified service personnel.
1
A605 Instructions