Motorola R-2550 Programming Reference Manual page 86

Communications system analyzer
Table of Contents

Advertisement

E3
Description:
Command Syntax:
Parameters:
Motorola Communications Analyzer
Programming Reference
E3 command
The
selects Tone A/B Sequence
and specifies the Tone A and Tone B frequencies, durations and delays.
E3 nl ,n2,n3,n4,n&n6
Description:
Tone A Frequency
optional:
Yes
Type:
<Decimal Numeric Program Datw
HZ
units:
Resolution:
0.1 Hz
Range:
0 through 19999.9
Reset:
1000.0 Hz
Description:
Tone A Duration
optional:
Yes
Type:
Units:
S
Resolution:
0.01 s
0 through 9.99
Range:
0.20 s
Reser
Description:
Tone A Delay
optional:
Yes
Type:
units:
S
Resolution:
0.01 s
Range:
0 through 9.99
0.10 s
Reset:
Tone
B Frequency
Description-
optional:
Yes
<Decimal Numeric Program Data>
Type:
units:
Hz
0.1 Hz
Resolution:
0 through 19999.9
Range:
2000.0 Hz
Reset:
3 as the
76
Tone A/B Sequence 3
synthesized modulation source,

Advertisement