Motorola R-2550 Programming Reference Manual page 77

Communications system analyzer
Table of Contents

Advertisement

ES
Description:
Command Syntax:
Parameters:
Notes:
The Es command sets the Tone Encode modulation source switch and specifies its
modulation level. If the synthesizer selection is not Tone A, Tone B, Tone A/B
Sequence, General Sequence, Tone Remote, 5/6 Tone, or Select V Tone the Invalid
Mode Error (09) is generated.
ES nl ,n2
Description:
Tone Modulation Switch
optional:
Yes
Type:
<Decimal Numeric Program Data>
units:
None
Resolution:
N/A
Range:
0: Continuous
1: Off
2: Burst
Reset:
1
Description:
Tone Modulation Level
Yes
Type:
units:
Mode dependent, see notes
Resolution:
Mode dependent, see notes
Range:
Mode dependent, see notes
0.000 v
Reset:
The following table describes the Units, Resolution, and Range values for the
Modulation Level based upon the RF-Control mode of the analyzer.
RF-Control
M o d e
Monitor/Narrow-Band
Monitor/Wide-Band
Generate/AM
Generate/FM/Narrow-Band
Generate/FM/Narrow-Band
Generate/PM/Wide-Band
Generate/PM/Wide-Band
67
Tone Encode Modulation Switch and Level
Units
Resolution
V
0.005 v
0.05 v
V
1 %
0.05 kHz
0.05 kHz
rad
0.01 rad
0.1 rad
rad
Motorola Communications Analyzer
Programming Reference
Range
0.000 - 0.795
0.00 - 7.95
0 - 99
0.00 - 9.95
0.00 - 9.95
0.50 - 2.00
2.0 - 10.0

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-2600

Table of Contents