Examples showing correct usage
RG 120.0230,0,40.0,1,0
Sets generate mode to 120.023 MHz at the GEN OUT port with a level setting of ~50.0 dBm with Wide-
Band FM modulation. This is the conventional method of configuring the analyzer for a generate mode by
supplying all five pertinent parameters.
RG
Sets the analyzer back to the previous settings for the last time the analyzer was configured in Generate
mode.
R G , l
Sets generate mode at the Transceiver port. No other parameters are changed. Note: rhe output level was
is in the range of -130 to -50 dBm, which is valid for the Transceiver port.
RG 120.223
Sets the generate mode to 120.223 MHz.
Sets the generate mode modulation type to FM. Note: the comma rhnr would normally separate the
Modulation Type parameter and the Bandwidth parameter is not specified since the Bandwidth parameter
is not specified.
Sets the generate mode modulation type to FM. Note: this command has rhe same e&ct ns example (5).
RG , 1, -130
Sets the generate mode at the Transceiver port with an output level of -130.0 dBm
0,
RG ,
-10
Sets the generate mode at the Gen Out port with an output level of -10.0 dBm.