Motorola R-2550 Programming Reference Manual page 75

Communications system analyzer
Table of Contents

Advertisement

Description:
Command Syntax:
Parameters:
Notes:
EQ
The
command sets the PL Encode modulation source switch and specifies its
modulation level. If the synthesizer is not selected to PL, the Invalid Mode En-or (09) is
generated.
Description:
PL Modulation Switch
optional:
Yes
Type:
units:
None
Resolution:
N/A
Range:
0: Continuous
1: Off
Reset:
0
Description:
PL Modulation Level
Optional:
Yes
Type:
<Decimal Numeric Program DOW
units:
Mode dependent, see notes
Resolution:
Mode dependent, see notes
Range:
Mode dependent, see notes
0.000 v
Reset:
The following table describes the Units, Resolution, and Range values for the
Modulation Level based upon the RF-Control mode of the analyzer.
RF-Control Mode
Monitor/Narrow-Band
Monitor/Wide-Band
Generate/AM
Generate/FM/Narrow-Band
Generate/FM/Narrow-Band
Generate/PM/Wide-Band
Generate/PM/Wide-Band
65
PL
Encode Modulation Switch and Level
Units
Resolution
0.005 v
V
V
0.05 v
1 %
0.05 kHz
0.05 kHz
0.01 rad
rad
rad
0.1 rad
Motorola Communications Analyzer
Programming Reference
Ranae
0.000 - 0.795
0.00 - 7.95
0 - 99
0.00 - 0 9.95
0.00 - 9.95
0.50 - 2.00
2.0 - 10.0