Fronius Datamanager 2.0 - Fronius Symo Advanced 10.0-3-M Operating Instructions Manual

Hide thumbs Also See for Symo Advanced 10.0-3-M:
Table of Contents

Advertisement

Fronius Datamanager 2.0

Controls, con-
nections and dis-
plays on the
Fronius
Datamanager 2.0
No.
(1)
24
(10)
(9)
(8)
Function
IP switch
For switching the IP address:
Switch position A
Default IP address with opening of the WLAN access point
Fronius Datamanager 2.0 uses the set IP address 169.254.0.180 to
establish a direct connection to a PC via LAN.
Setting the IP switch to position A also opens an access point to en-
able a direct WLAN connection to the Fronius Datamanager 2.0.
Access data for this access point:
Network name: FRONIUS_240.XXXXXX
Code: 12345678
Access to the Fronius Datamanager 2.0 is possible:
-
Using the DNS name "http://datamanager"
-
Using the IP address 169.254.0.180 for the LAN interface
-
Using the IP address 192.168.250.181 for the WLAN access
point
Switch position B
Assigned IP address
The Fronius Datamanager 2.0 uses an assigned IP address (factory
setting dynamic (DHCP))
The IP address can be set on the Fronius Datamanager 2.0 website.
(1)
(2)
(3)
(7)
(6)
(5)
(4)