Fronius Datamanager 2.0; Controls, Connections And Displays On The Fronius Datamanager - Fronius Symo 3.0-3-S Operating Instructions Manual

Grid-connected inverter
Hide thumbs Also See for Symo 3.0-3-S:
Table of Contents

Advertisement

Fronius Datamanager 2.0

Controls, connec-
tions and dis-
plays on the
Fronius Dataman-
ager
No. Function
(1)
18
(10)
(9)
(8)
IP switch
For switching the IP address:
Switch position A
Default IP address with opening of the WLAN access point
Fronius Datamanager 2.0 uses the set IP address 169.254.0.180 to establish a
direct connection to a PC via LAN.
Setting the IP switch to position A also opens an access point to enable a direct
WLAN connection to the Fronius Datamanager 2.0.
Access data for this access point:
Network name: FRONIUS_240.XXXXXX
Key: 12345678
Access to the Fronius Datamanager 2.0 is possible:
-
Using the DNS name "http://datamanager"
-
Using the IP address 169.254.0.180 for the LAN interface
-
Using the IP address 192.168.250.181 for the WLAN access point
Switch position B
Assigned IP address
The Fronius Datamanager 2.0 uses an assigned IP address (factory setting dy-
namic (DHCP))
The IP address can be set on the Fronius Datamanager 2.0 website.
(1)
(2)
(3)
(7)
(6)
(5)
(4)