Status diagnostics and troubleshooting

Status code dis-
The inverter performs a system self-diagnosis that automatically detects many
play
faults that may occur and shows them on the display. This means you are
promptly made aware of malfunctions in the inverter or the photovoltaic system,
or of any installation or operating faults.
If the system self-diagnosis has detected a specific fault, the associated status
code will be shown on the display.
IMPORTANT! Status codes may sometimes appear briefly as a result of the in-
verter's control response. If the inverter then continues working with no sign of
any problem, this means that there was no fault.
Total failure of
If the display fails to come on some time after sunrise:
the display
-
Class 1 status
Class 1 status codes generally only arise momentarily and are caused by the pub-
codes
lic grid.
Example: The grid frequency is too high and the inverter may not feed any energy
into the grid owing to a standard. There is nothing wrong with the device.
The initial response of the inverter is to disconnect itself from the grid. The grid
is subsequently checked during the stipulated monitoring period. If no further
problem has been detected by the end of this period, then the inverter will re-
sume feeding energy into the grid.
The GPIS SoftStart function is activated according to the country setup:
After cutting out due to an AC error, the output power of the inverter is continu-
ously increased in line with the national guidelines.
Code
Description
102
AC voltage too high
103
AC voltage too low
105
AC frequency too high
106
AC frequency too low
107
No AC grid
108
Stand-alone operation de-
tected
112
RCMU error
Check the AC voltage on the inverter connection sockets:
the AC voltage must be 220/230 V (+ 10 % / - 5 %) or 380/400 V (+ 10 % / -
5 %).
Behaviour
Following careful testing and
when the grid conditions are
within the permissible range
again, the inverter will resume
feeding energy into the grid.
Remedy
Check grid connections;
if this status code keeps re-
curring, contact your system
fitter