10
|
Configuration
10.6.2 Tank
Installer reference guide
70
Overview
The following items are listed in the submenu:
5
Operation
Malfunctioning
Tank
User settings
Information
Tank setpoint screen
You can set the domestic hot water temperature using the setpoint screen. For
more information about how to do this, see
Powerful operation
You can use powerful operation to immediately start heating up the water to the
preset value (Comfort setpoint). This activates both heat pump and electrical
booster heater, which results in extra energy consumption. If powerful operation is
active,
will be shown on the home screen.
To activate powerful operation
Activate or deactivate Powerful operation as follows:
1 Go to [5.1]: Tank > Powerful operation
2 Turn powerful operation Off or On.
Usage example: You immediately need more hot water
If you are in the following situation:
▪
You already consumed most of your hot water.
▪
You cannot wait for the next scheduled action to heat up the storage tank.
Then you can activate DHW powerful operation.
Advantage: The storage tank is immediately heated up to the Comfort
setpoint.
[5] Tank
Setpoint screen
[5.1] Powerful operation
[5.2] Comfort setpoint
[5.3] Eco setpoint
[5.4] Reheat setpoint
[5.5] Schedule
[5.6] Heat up mode
[5.7] Disinfection
[5.8] Maximum
[5.9] Hysteresis
[5.A] Hysteresis
[5.B] Setpoint mode
[5.C] WD curve
[5.D] Margin
[5.E] WD curve type
[5.F] Priority schedule
[5.G] Operation mode
[5.H] Quick mode timer