EQUIPMENT OR ACCESSORIES COULD RESULT IN ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE SPECIFICALLY DESIGNED FOR USE WITH THE EQUIPMENT AND HAVE THEM INSTALLED BY A PROFESSIONAL.
VERVIEW OF THE UNIT The total system (indoor unit and outdoor unit) is designed Accessories supplied with the domestic hot water tank for combination with a Daikin domestic hot water tank. In case another tank is being used in combination with the figure Daikin indoor unit, Daikin cannot guarantee neither good operation nor reliability of the system.
Return outlet connection to the main EKHBRD indoor unit at the bottom of the tank (quick coupling) Temperature and pressure relief valve (15 mm Male) Knockout holes for water piping Levelling feet (on EKHBRD unit) Domestic hot water tank model EKHTSU200AA 2010 mm 1847 mm EKHTSU260AA 2285 mm...
EKHTSU NSTALLATION OF THE DOMESTIC HOT Installing and commisioning the domestic hot water tank WATER TANK Installing the hot water tank on top of the indoor unit Installation shall be done by a licensed technician, the Unpack the domestic hot water tank according to the choice of materials and installation shall comply with instructions mentioned on the unpacking instruction sheet.
Page 7
4 Put the sleeve on the valve and turn the valve so that the 7 Put the turn knob on the valve motor cover as shown below. sleeve is positioned according to the figure below. Room heating Domestic hot water tank Make sure that the turn knob is completely pushed in to allow the turn knob being operated automatically by the unit.
Page 8
Mount the tank module on top of the indoor unit using the lifting Fix the side bottom decoration panels of the domestic hot water holes. tank to the indoor unit. Decoration panel Because of the weight of the domestic hot water tank, Quick fixation hole it is advised to handle and lift it with two persons.
Page 9
Note: only relevant field wiring is shown. 13 Reattach the temperature 1 2 3 and pressure relief valve 3-way insulation piece, and both valve front decoration panels of >50 mm N Y L the domestic hot water tank. 14 Reattach front decoration panel of the indoor unit.
EKUHWHTA NSTALLATION OF THE KIT ON THE DOMESTIC HOT WATER TANK All pipework and fittings must be flushed free of all flux and debris prior to the fitting of controls of this kit. Failure to do this may cause irreparable damage to the controls. All cautions as under chapter "Installation of the EKHTSU domestic hot water tank"...
Local Authority of intention to install. Remove the insulation piece to get acces to the factory fitted Use only manufacturer's recommended spare parts. Contact your local Daikin dealer. temperature and pressure relief valve. Manually operate the Installed by temperature and pressure relief valve to ensure free water flow name through discharge pipe.
If the cause of the problem cannot be found, Depending on local water conditions, annual inspection of the call your local Daikin dealer. integral line strainer, pressure reducing valve cartridge and seating may be necessary.
IPOSAL REQUIREMENTS Dismantling of the unit and treatment of parts must be done in accordance with relevant local and national legislation. ECHNICAL SPECIFICATIONS Domestic hot water tank specifications EKHTSU200AA EKHTSU260AA • Storage capacity • Material Stainless steel Stainless steel •...
Need help?
Do you have a question about the EKHTSU200AA and is the answer not in the manual?