Daikin EKHWET-BV3 Installer's Reference Manual page 34

Domestic hot water tank
Hide thumbs Also See for EKHWET-BV3:
Table of Contents

Advertisement

7
|
Unit installation
Table 2: Minimum release height
Take the following into account:
• For intermediate floor areas, use the column with the lower value. Example: If the floor area is 5 m², use the
column of 4.00 m².
• For intermediate refrigerant charges, use the row with the higher value. Example: If the refrigerant charge is
2.35 kg, use the row of 2.4 kg.
Charge (kg)
2.2
2.3
2.4
2.5
2.6
Table 3: Minimum bottom opening area for natural ventilation
Take the following into account:
• Use the correct table. For intermediate refrigerant charges, use the table with the higher value. Example: If the
refrigerant charge is 2.34 kg, use the table of 2.4 kg.
• For intermediate floor areas, use the column with the lower value. Example: If the floor area is 5 m², use the
column of 4.00 m².
• For intermediate release height values, use the row with the lower value. Example: If the release height is
2.20 m, use the row of 2.05 m.
• A
: Bottom opening area for natural ventilation.
nv
• A
: Minimum bottom opening area for natural ventilation.
nv-min
• (*): Already OK (no ventilation openings needed).
Release height (m)
1.23
1.45
1.65
1.85
2.05
2.25
2.45
2.65
Release height (m)
1.23
1.45
1.65
1.85
2.05
2.25
2.45
2.65
Release height (m)
1.23
1.45
1.65
1.85
2.05
2.25
Installer reference guide
34
Minimum release height (m)
2,00
4,00
4,88
2,49
5,10
2,60
5,32
2,71
5,53
2,82
5,75
2,93
A
(dm²) – In case of Refrigerant charge=2.2 kg
nv-min
2,00
4,00
4,7
3,1
4,0
2,3
3,6
1,7
3,2
1,2
2,8
0,7
2,5
0,3
2,2
(*)
1,9
(*)
A
(dm²) – In case of Refrigerant charge=2.4 kg
nv-min
2,00
4,00
5,2
3,6
4,6
2,8
4,1
2,2
3,6
1,7
3,2
1,2
2,9
0,7
2,6
0,3
2,3
(*)
A
(dm²) – In case of Refrigerant charge=2.6 kg
nv-min
2,00
4,00
5,8
4,2
5,1
3,3
4,5
2,7
4,1
2,1
3,7
1,6
3,3
1,2
Floor area (m²)
6,00
8,00
1,70
1,47
1,77
1,53
1,84
1,59
1,91
1,65
1,99
1,71
Floor area of room A (m²) [! NOT room A + room B !]
6,00
8,00
1,5
0,7
0,6
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
Floor area of room A (m²) [! NOT room A + room B !]
6,00
8,00
2,0
1,3
1,1
0,2
0,3
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
Floor area of room A (m²) [! NOT room A + room B !]
6,00
8,00
2,6
1,9
1,6
0,8
0,8
(*)
0,2
(*)
(*)
(*)
(*)
(*)
10,00
12,00
(*)
(*)
1,38
(*)
1,43
(*)
1,49
1,37
1,54
1,42
10,00
12,00
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
10,00
12,00
0,6
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
10,00
12,00
1,3
0,6
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
(*)
R32 Split series – Domestic hot water tank
4P680077-1A – 2022.11