Dear Customer, Thank you for choosing a Pfeiffer Vacuum product. Your new turbopump is designed to support you by its performance, its perfect operation and without interfering your individual application. The name Pfeiffer Vacuum stands for high-quality vacuum technology, a comprehensive and complete range of top-quality products and first-class service.
5.2.3 Telegram example 1 5.2.4 Telegram example 2 5.2.5 Data types Parameter set General Control commands Status requests Reference value inputs Additional parameters for Profibus Additional parameters for the control unit Operation Configuring the connections with the Pfeiffer Vacuum parameter set 3/56...
Page 4
Switching off the turbopump Operation monitoring 7.6.1 Operating mode display via LED 7.6.2 Temperature monitoring Malfunctions General Error codes Warning and malfunction messages when operating with control units Service solutions by Pfeiffer Vacuum EC Declaration of Conformity UK Declaration of Conformity 4/56...
Page 5
List of tables List of tables Tbl. 1: Stickers on the product Tbl. 2: Abbreviations used in this document Tbl. 3: Permissible ambient conditions Tbl. 4: Features of the device variant Tbl. 5: Delivered drive power depending on the supplied mains voltage Tbl.
Page 6
List of figures List of figures Fig. 1: Connection panel TC 1200 PB Fig. 2: Diagram and assignments of the connection panel Fig. 3: Profibus address selector switch Fig. 4: Illustration of the Profibus modules Fig. 5: Schematic diagram of power characteristics, example of heavy gases [P:027] = 0 Fig.
Keep the manual for future consultation. 1.1 Validity This operating instructions is a customer document of Pfeiffer Vacuum. The operating instructions de- scribe the functions of the named product and provide the most important information for the safe use of the device. The description is written in accordance with the valid directives. The information in this op- erating instructions refers to the product's current development status.
AI / AO Analog Input / Analog Output Ampere Interrupting Capacity Display Control Unit (Pfeiffer Vacuum display and control unit) DI / DO Digital Input / Digital Output Rotation speed value of a vacuum pump (frequency, in rpm or Hz) Device master data (Profibus) Handheld Programming Unit.
Safety 2 Safety 2.1 General safety information The following 4 risk levels and 1 information level are taken into account in this document. DANGER Immediately pending danger Indicates an immediately pending danger that will result in death or serious injury if not observed. ►...
Safety DANGER Danger to life from electric shock Power supply packs that are not specified or are not approved will lead to severe injury to death. ► Make sure that the power supply pack meets the requirements for double isolation between mains input voltage and output voltage, in accordance with IEC 61010-1 IEC 60950-1 and IEC 62368-1.
Safety Infringement of conformity due to modifications to the product The Declaration of Conformity from the manufacturer is no longer valid if the operator changes the original product or installs additional equipment. ● Following the installation into a system, the operator is required to check and re-evalu- ate the conformity of the overall system in the context of the relevant European Direc- tives, before commissioning that system.
Safety 2.5 Proper use ● The electronic drive unit is used exclusively for the operation of Pfeiffer Vacuum turbopumps and their accessories with a Profibus DP ® bus system. 2.6 Foreseeable misuse Improper use of the product invalidates all warranty and liability claims. Any use that is counter to the purpose of the product, whether intentional or unintentional, is regarded as misuse, in particular: ●...
ID no. 000021320. 3.2 Product features The type TC 1200 PB electronic drive unit is a fixed component of the turbopump. The purpose of the electronic drive unit is to drive, monitor and control the entire Turbopump. The electronic drive unit is equipped with an integrated extended voltage supply.
AC in Housing plug HAN 3A for the voltage supply accessory M12 socket with screw lock for the connection of Pfeiffer Vacuum accessories. The use of a Y-distributor permits the double allocation of a connection. PV.can M12 bushing with threaded coupling and LED for Pfeiffer Vacuum service purpos-...
Installation 4 Installation 4.1 Connecting diagram DANGER Danger to life from electric shock Power supply packs that are not specified or are not approved will lead to severe injury to death. ► Make sure that the power supply pack meets the requirements for double isolation between mains input voltage and output voltage, in accordance with IEC 61010-1 IEC 60950-1 and IEC 62368-1.
Page 17
Installation n.c. n.c. n.c. Accessory A2 Accessory B2 24 V DC** 24 V DC** Accessory A1 Accessory B1 + 24 V DC* out DI Motor pump CAN-H DI Pumping station 24 V DC*** DI Standby GND*** CAN-L AI+ 0-10 V DC +5VDC** out AI- GND RxD/TxD-N...
1. Establish the Profibus connection in compliance with the applicable guidelines. 2. Use a suitable connection cable and components from the Pfeiffer Vacuum line of accessories. 3. Use a Profibus master to configure the Profibus interface with the GSD file included in the turbo- pump shipment.
= 50 V DC; I = 1 A) DO remote priori- GND: off; V+: Remote priority active RS-485 D+ in accordance with the specification and Pfeiffer Vacuum proto- RS-485 D- Ground (GND) Reference earth for all digital inputs and outputs Tbl. 8: Terminal lay-out of 26-pin "remote"...
Terminal lay-out of the power supply connector Establishing mains connection 1. Order a corresponding power supply cable from the Pfeiffer Vacuum accessories range. 2. Assemble your own power supply cable using the HAN 3A connecting socket from the shipment. 3. Plug mains cable into the mains connection "AC in".
Overview of the Profibus modules ● The data format is always "high word/byte first" (Motorola). ● All Pfeiffer Vacuum parameters of the data type 0 ,1 ,2 and 7 can be used for parameter channel PPO1 and the parameterization data.
Interfaces Byte Description 0, bit 7 0: Parameter for "start-up configuration" 1: Parameter for "fail-safe action" 0, bit 6 0: Parameter value is integer 1: Parameter value floating point (in accordance with IEEE 754) 2 to 3 Parameter number 4 to 7 Parameter value Tbl.
Interfaces Error number Description Invalid parameter number, function already used in control word Parameter value not changeable Below/above value range Incorrect data type Invalid request Parameter value not readable Invalid format Tbl. 16: Error numbers (response "PPO1") Output data (O) Input data (I) Reserved (do not evaluate) Enable vents...
Interfaces 5.1.4 Profibus module "control/status word" Byte Control/status bits 0 – 1 Control word (see PPO1) Status word (see PPO1) Tbl. 19: Output and input data ("control/status word") 5.1.5 Profibus module "control/status byte" Byte Control/status bits Control word (see PPO1) Status word (see PPO1) Tbl.
Profibus: Expanded diagnostics data 5.2 Pfeiffer Vacuum protocol for RS-485 interface 5.2.1 Telegram frame The telegram frame of the Pfeiffer Vacuum protocol contains only ASCII code characters [32; 127], the exception being the end character of the telegram C . Basically, a host (e.g.
Interfaces 5.2.3 Telegram example 1 Data query Current rotation speed (parameter [P:309], device address: "123") --> ASCII Data response: 633 Hz Current rotation speed (parameter [P:309], device address: "123") --> ASCII 5.2.4 Telegram example 2 Control command Switch on the pumping station (parameter [P:010], device address: "042" -->...
Each parameter has a three-digit number and a description. The parameter can be accessed via Pfeiffer Vacuum control units or externally via RS-485 using Pfeiffer Vacuum protocol. The vacuum pump starts in standard mode with factory default pre-set parameters.
Page 28
Parameter set Display Description Functions Data Unit min. max. type cess fault type Cfg DO2 Output DO2 0 = Rotation speed switchpoint configuration reached 1 = No error 2 = Error 3 = Warning 4 = Error and/or warning 5 = Set rotation speed reached 6 = Pump on 7 = Pump accelerating 8 = Pump decelerating...
Page 29
Parameter set Display Description Functions Data Unit min. max. type cess fault type Cfg Acc A1 Configuration 0 = fan (continuous operation) accessory 1 = Venting valve, closed with- connection out current 2 = Heating 3 = Backing pump 4 = Fan (temperature control- led) 5 = Sealing gas 6 = Always "0"...
Parameter set Display Description Func- Data Access Unit min. max. tions type type fault OpHrsElec Drive electronics operating 65535 hours Nominal Spd Nominal rotation speed 999999 (Hz) DrvPower Drive power 999999 PumpCycles Pump cycles 65535 TempPwrStg Final stage temperature °C 999999 TempElec Electronics temperature...
The basic parameter set is set in the electronic drive unit ex-factory. For controlling con- nected external components (e.g. vacuum measuring equipment), additional parameters (extended parameter set) are available in the corresponding Pfeiffer Vacuum control units. ● Refer to the corresponding operating instructions of the respective components.
Page 33
Parameter set Indicator Description Functions Data Access Unit min. max. type type fault Pressure Actual pressure value 1·10 1·10 (ActiveLine) Ctr Name Control unit type Ctr Software Control unit software version Gauge type Type of pressure gauge Param set Parameter set 0 = Basic pa- rameter set 1 = Extended...
Operation 7 Operation 7.1 Configuring the connections with the Pfeiffer Vacuum parameter set The electronic drive unit is pre-configured with the factory default basic functions and is ready for opera- tion. For individual requirements, you can configure most connections for the electronic drive unit with the parameter set.
► Make sure that the gas mode is set correctly by [P:027] in the electronic drive unit. ► Consult Pfeiffer Vacuum before you use gases with higher molecular masses (> 80). High gas throughput and high rotation speed lead to strong friction heating of the rotor. To avoid over- heating, power to rotation speed characteristics are implemented in the electronic drive unit.
Operation P max [P:708] Fig. 5: Schematic diagram of power characteristics, example of heavy gases [P:027] = 0 Power consumption Power characteristic in gas mode "0" (gases with molecu- lar mass > 39, e.g. Argon) Rotation speed Power characteristic in gas mode "1" (gases with molecu- lar mass ≤...
Page 38
Operation Rotation speed switch point 1 [P:017] = 0 f (%) [P:701] [P:010] [P:302] Process Fig. 6: Rotation speed switch point 1 active Adjusting rotation speed switch point 1 Signal output and status parameters are based on the set value for the rotation speed switch point 1 [P:701].
3. Check the set rotation speed (parameter [P:308] or [P:397]). 7.2.6 Standby Pfeiffer Vacuum recommends standby mode for the turbopump during process and production stops. When standby mode is active, the electronic drive unit reduces the rotation speed of the turbo pump.
Fluctuations in the power consumption of idling turbopumps and varying fore-vac- uum pressures of the backing pumps require individual settings of the interval operation. Pfeiffer Vacuum recommends interval operation between 5 and 10 hPa. A pressure gauge and a dosing valve are required to set the switching thresholds.
2. Use this signal for the control of a fore-vacuum safety valve. 7.2.9 Backing pump standby mode In case you are using a Pfeiffer Vacuum backing pump with rotation speed control, this can be used in standby mode by configuring the digital output [P:019] or [P:024]. The power consumption of the turbo- pump has a direct influence on the rotation speed of the backing pump.
The digital inputs at the "remote" connection are used to switch various electronic drive unit functions. As a factory default, inputs DI1 – DI2 have that can be configured with the Pfeiffer Vacuum parameter set via Profibus or the RS-485 interface.
Operation Status Description Turbo pump motor on open Turbo pump motor off Tbl. 39: DI motor pump/pin 3 DI pumping station / Pin 4 Control of connected pumping station components (e.g. backing pump, venting valve, air cooling). If pin 3 (motor) is activated at the same time, the turbopump starts up. Any pending error messages are reset by eliminating the cause.
The digital outputs at the "remote" connection have a maximum load limit of 24 V/50 mA per output. All outputs listed below are configurable with the Pfeiffer Vacuum parameter set via Profibus or the RS-485 interface (description relates to factory settings).
► Connect only suitable devices to the bus system. You can connect a Pfeiffer Vacuum control unit or an external PC via pins 24 and 25 at the "remote" connection of the electronic drive unit. A USB interface (PC) can be connected via the USB/RS-485 converter.
7.6.1 Operating mode display via LED LEDs on the electronic drive unit show the basic operating states of the turbopump. A differentiated er- ror and warning display is possible in case of operations with the Pfeiffer Vacuum display and control panel.
Warnings (* Warning F –––– *) do not cause components to be switched off. Handling malfunction messages 1. Read out error codes via Pfeiffer Vacuum control units or a PC. 2. Remove the cause of the malfunction. 3. Reset the malfunction message with parameter [P:009].
Page 48
Malfunctions Error Problem Possible causes Remedy code Err043 Internal configuration er- ● Device defective ● Contact Pfeiffer Vacuum Service Err044 Excess temperature, ● Insufficient cooling ● Improve the cooling electronics ● Check the operating conditions Err045 Excess temperature, ● Insufficient cooling ●...
Page 49
Problem Possible causes Remedy code Err800 Magnetic bearing over- ● Impacts, vibrations ● Contact Pfeiffer Vacuum Service flow ● Device defective ● Check the operating conditions ● Only acknowledge for rotational speed f = 0 Err802 Magnetic bearing sen- ● Calibration values invalid ●...
We are always focused on perfecting our core competence – servicing of vacuum components. Once you have purchased a product from Pfeiffer Vacuum, our service is far from over. This is often exactly where service begins. Obviously, in proven Pfeiffer Vacuum quality.
Page 52
Service solutions by Pfeiffer Vacuum 5. Prepare the product for transport in accordance with the provisions in the contamination declaration. a) Neutralize the product with nitrogen or dry air. b) Seal all openings with blind flanges, so that they are airtight.
This declaration of conformity has been issued under the sole responsibility of the manufac- turer. Declaration for product(s) of the type: Electronic drive unit TC 1200 PB We hereby declare that the listed product satisfies all relevant provisions of the following European Directives. Electromagnetic compatibility 2014/30/EU...
Semi F47-0200 EN IEC 61326-1:2021 Semi S2-0706 The manufacturer's authorized representative in the United Kingdom and the authorized agent for compiling the technical documentation is Pfeiffer Vacuum Ltd, 16 Plover Close, In- terchange Park, MK169PS Newport Pagnell. Signature: Pfeiffer Vacuum GmbH Berliner Straße 43...
Need help?
Do you have a question about the TC 1200 PB and is the answer not in the manual?
Questions and answers