3.
LCD Screen operation - Section G
Filter
ZenithHydroTap G4 allows the user to adjust filter life and edit filter usage.
Page 22 of 32
Note: The filter life may be set as a
function of Litres used, or in months
from the filter change. When the first of
these functions is reached (i.e. Litres or
months expired), the filter warning light
will be illuminated on the tap.
Either of these functions may be
disabled (See below).
To edit the filter life:
1. Press the [MENU] button for main
menu.
2. Press the [Setting] button.
3. Press the [Filter] button.
4. Press the [Int / Ext Filter Life] button.
5. To change filter life, first select
(Litres) or (Months), then press the up
or down arrows to edit filter life.
Note:
Filter Life increases in 500 litres incre-
ments to a maximum of 10000 litres.
Factory set at 6000 litres.
To edit the filter usage:
This function is to reset the Filter
Change display after a filter has
reached the end of its life (refer to
"Replace Filter Instructions" section of
this document).
Press the [MENU] button for main
1.
menu.
Press the [Setting] button.
2.
Press the [Filter] button.
3.
Press the [Edit Filter] button for
4.
Internal or External filter.
To edit, select Edit Usage(Litres) or
5.
Edit Usage (Months), then adjust
using the up or down arrows.
Press [HOME] to return to the
6.
Home screen.