Laser Interface; Power Supply Connector - JPT YDFLP-E-80&100-M7-M-R User Manual

Pulsed fiber laser
Table of Contents

Advertisement

2. Laser Interface

2.1 Power Supply Connector

Please refer to Figure7 & Table 6 in below to install the power cable to the 48V DC power
supply, and ensure the DC power supply can provide sufficient output power. Please also note
the polarity of the cable when connecting. The "main+" and "control+" at the end of the power
cable are 48V DC positive, "main-" and "control-" are 48V DC negative, "Earth" is the ground
wire.
"Main +" and "Main -" are power supply pins of laser pump, "Control +" and "Control -"
are power supply pins of control circuit. If independent power supply function is not required,
main and control power cable can be used in parallel.
The power interface of the laser is DB-7W2 plug (male), and the pin distribution is as follows:
PIN#
A1
A2
1,3,4
Note: Housekeeping (main and control power supply independent) function can be customized.
Figure 7 Diagram of the power supply cable
Table 6 Definition of power supply cable
+48VDC,laser pump power supply
2
+48VDC,control circuit power supply
5
YDFLP-E-80&100-M7-M-R User Manual
Description
-48VDC
No need to connect
Ground wire
8
File Number:
JG-MCYF-SM-0039