JPT YDFLP-E-80&100-M7-M-R User Manual page 14

Pulsed fiber laser
Table of Contents

Advertisement

DB25 PIN#
1-8
IP0-IP7 Power Control
Latches power setting of the laser, effective during rising edge(This feature
9
can be enabled in the GUI)
GND
10-15
Description: PIN10-15 have connected to the ground inside the fiber laser,
only need to connect control card GND with one of the Pins.
Warning signal
16,21
Description:16 low level,21 high level: Normal
Emission Modulation input (PA)
19
HIGH= Emission ON
LOW=Emission OFF
20
Frequency Modulation (TTL)
Emergency Stop signal
High level: Normal; Low level: Emergency Stop (this function can be
selected in GUI)
23
Emergency stop signal is from low to high, need to detect the rising edge
of MO firstly, then the laser can be re-emitted.
Red beam ENABLE (Red Beam is preferred when Laser and Red Beam
are mutually exclusive. * refer to note2)
Pulse width adjustment ENABLE (Please refer to the following pulse
22
width control section for specific control mode).
High Level: Red Beam On
Low Level: Red Beam Off
MO signal for turn on/off
18
HIGH: ON
LOW: OFF
17,24,25
No need to connect
Note 1: 4.6-5.4V will be recognized as TTL high; 0-0.5V will be recognized as TTL low.
Note 2: The default setting is red beam preferred. Red beam Pin22 signal has higher priority than
MO and PA signal. When Pin22 signal is high, MO and PA signal will be shut down internally.
The laser can be emitted by restarting MO and PA after Pin22 signal is low. Priority mode can be
set up in GUI (please refer to Chapter 3.1.2).
YDFLP-E-80&100-M7-M-R User Manual
Table 8 DB25 Interface Definition
Definition
16 low level,21 low level: temperature alarm