Service Life of the Battery Pack
If any condition described below is observed, the
battery pack is at the end of its service life. Re-
place it with a new one.
• Although the battery pack has been properly
charged (fully charged), a great drop in tying
time has been noticed.
NOTICE
Do not charge the battery pack when this hap-
pens. If the motor's rotational speed slows
down, the power of the battery pack is consid-
ered to be nearly depleted. Using the tool
more will cause it to overdischarge, resulting
in a shortened service life of the battery pack
and also in functional trouble of the tool's
main body.
NOTICE
Do not use a battery pack when its service life
is finished.
This will cause functional trouble in the tool's
main body. Also charging a battery pack that
is out of service life will lead to functional trou-
ble in the battery charger.
Recycling a Li-ion Battery
The MAX battery pack uses a Li-ion battery, it
may be illegal to dispose of this battery into the
municipal waste system. Check with your local
solid waste officials for details in your area for re-
cycling options or proper disposal.
CAUTION
When disposing of the battery pack, make
sure to put a pack cap on its terminal (with in-
sulating tape securing it) to prevent short cir-
cuits.
5. OPERATING INSTRUC-
TIONS
LOCK
1. How to set the Tie-Wire
WARNING
• Be sure to set the Main switch to off, to lock
the Trigger, and detach the Battery pack.
Release Stopper
1 Press the Release Lever of this equipment,
and confirm that the Release Lever is caught
in the Release Stopper.
18
OFF
Release Lever