Troubleshooting by symptom

Use this information to find solutions to problems that have identifiable symptoms.
To use the symptom-based troubleshooting information in this section, complete the following steps:
1. Check the event log of the application that is managing the server and follow the suggested actions to
resolve any event codes.
• If you are managing the server from the Lenovo XClarity Administrator, begin with the Lenovo XClarity
Administrator event log.
• If you are managing the server from the Chassis Management Module 2, begin with the Chassis
Management Module 2 event log.
• If you are using some other management application, begin with the Lenovo XClarity Controller event
log.
For more information about event logs, see
2. Review this section to find the symptoms that you are experiencing and follow the suggested actions to
resolve the issue.
3. If the problem persists, contact support (see

Hard disk drive problems

Use this information to resolve issues related to the hard disk drives.
"Server cannot recognize a hard drive" on page 157
"Multiple hard drives fail" on page 158
"Multiple hard drives are offline" on page 158
"A replacement hard disk drive does not rebuild" on page 158
"Green hard disk drive activity LED does not represent actual state of associated drive" on page 159
"Yellow hard disk drive status LED does not represent actual state of associated drive" on page 159
Server cannot recognize a hard drive
Complete the following steps until the problem is solved.
1. Observe the associated yellow hard disk drive status LED. If the LED is lit, it indicates a drive fault.
2. If the status LED is lit, remove the drive from the bay, wait 45 seconds, and reinsert the drive, making
sure that the drive assembly connects to the hard disk drive backplane.
3. Observe the associated green hard disk drive activity LED and the yellow status LED and perform
corresponding operations in different situations:
• If the green activity LED is flashing and the yellow status LED is not lit, the drive is recognized by the
controller and is working correctly. Run the diagnostics tests for the hard disk drives. When you start
a server and press the key according to the on-screen instructions, the LXPM is displayed by default.
(For more information, see the "Startup" section in the LXPM documentation compatible with your
server at
https://sysmgt.lenovofiles.com/help/topic/lxpm_frontend/lxpm_product_page.html
perform hard drive diagnostics from this interface. From the Diagnostic page, click Run Diagnostic
➙ HDD test/Disk Drive Test.
• If the green activity LED is flashing and the yellow status LED is flashing slowly, the drive is
recognized by the controller and is rebuilding.
• If neither LED is lit or flashing, check whether the hard disk drive backplane is correctly seated. For
details, go to step 4.