Technical Data - Mitsubishi Electric E1032 Installation Manual

Operator terminal
Hide thumbs Also See for E1032:
Table of Contents

Advertisement

3

Technical Data

Parameter
Front panel, W x H x D 202 x 187 x 6 mm
Mounting depth
Front panel seal
Rear panel seal
Keyboard material
Reverse side material
Weight
Serial port RS422/
RS485
Serial port RS232C
Ethernet
USB
Flash memory for
application
Real time clock
Power consumption at
rated voltage
Display
Active area of display,
W x H
Fuse
Power supply
Ambient temperature
Storage temperature
Relative humidity
EMC tests on the
operator terminal
UL, cUL approvals
(when product or
packing is marked)
DNV
NEMA
* See section
Chemical Resistance
Mitsubishi Electric, MA00816
56.9 mm (156.9 mm including clearance)
IP 66
IP 20
Membrane switch keyboard with metal domes. Overlay film
of Autotex F157 * with print on reverse side. 1 million
operations.
Powder-coated aluminum
0.875 kg
25-pin D-sub contact, chassis-mounted female with
standard locking screws 4-40 UNC.
9-pin D-sub contact, male with standard locking screws 4-40
UNC.
Shielded RJ 45
Host type A (USB 1.1), max output current 500 mA
12 MB (incl. fonts)
±20 PPM + error because of ambient temperature and supply
voltage.
Total max error: 1 min/month at 25 C
Minimum life of the real time clock battery: 3 years
Temperature coefficient: 0.004 ppm/ C
Normal: 0.15 A
Maximum: 0.35 A
FSTN-LCD. 240 x 64 pixels, monocrome transflective.
LED backlight lifetime at the ambient temperature of
+25 C: >50,000 h.
127.0 x 33.8 mm
Internal DC fuse, 2.0 AT, 5 x 20 mm
+24V DC (20 - 30V DC). 3-pin jack connection block.
CE: The power supply must conform with the requirements
for SELV or PELV according to IEC 950 or IEC 742.
UL: The power supply must conform with the requirements
for class II power supplies.
Vertical installation: 0 to +50 C
Horizontal installation: 0 to +40 C
-20 to +70 C
5 - 85 % non-condensed
The operator terminal conforms with the essential protection
requirements in article 4 of the directive 89/336/EEC. Noise
tested according to EN61000-6-3 emission and EN61000-6-2
immunity.
UL 1604 Class I, Div 2 / UL 508 / UL 50 4x indoor use only
Ceritfication in progress
4x indoor use only
for more information.
Technical Data
E1032
2
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents