Technical Details/Regulations - Bellfires VIEW BELL DERBY 3 CF Installation Instructions & Manual For Maintenance

Gas fi res with closed combustion system
Hide thumbs Also See for VIEW BELL DERBY 3 CF:
Table of Contents

Advertisement

Bellfi res
7

TECHNICAL DETAILS/REGULATIONS

National installation regulations:
• Gas safety installation and use regulations 1998 plus all relevant
safety and building regulations concerning fi re installation
• Document J: Combustion appliances and fuel storage systems
Model
Gas
Country
Product identifi cation no
Type of appliance under CE-norm
Category of appliance
Nominal heat input
(Gross calorifi c value)
Nominal heat output
Effi ciency class
NOx-class
Gas rate (max.)
Supply pressure
Burner pressure (max.) Hot
Burner pressure (max.) Cold
Burner pressure (min.)
Primary air inlet burner Rear
Primary air inlet burner Front
Gas regulator block (remote control)
Main burner
Main burner injector Rear
Main burner injector Front
Pilot light burner
Pilot light burner injector
Gas connection
Concentric fl ue system connection
Installation instructions
: VIEW BELL DERBY 3 CF (Centre Fire)
: NATURAL GAS
: GB; Great Britain/IE; Ireland
: 0063CM3684
: C
/ C
/ C
11
31
31S
: I
natural gas G20
2H
: 11.5 kW
: 8.8 kW
: 1 (85%)
: 5
3
: 1.10 m
/hr.
s
: 20.0 mbar
: 13.0 mbar(*)
: 12.3 mbar(**)
: 0.5 mbar(***)
: 1x Ø10.0 mm
: 1x Ø10.0 mm
: Mertik GV 60
: Centre Fire 561x130 mm
: no 200 (= 1x Ø2.00 mm)
: no 200 (= 1x Ø2.00 mm)
: SIT 0.145.019
: no 36 (SIT 0.977.091)
: 3/8" G / Ø12 mm
: Ø100 mm - Ø150 mm or
Ø130 mm - Ø200 mm
English
: BUTANE / PROPANE
: GB; Great Britain/IE; Ireland
: 0063CM3684
: C
/ C
/ C
11
31
31S
: I
butane/propane G30/G31
3B/P
: Butane (G30) : 10.0 kW
Propane (G31) : 8.5 kW
: 6.6 - 7.7 kW
: 1 (85%)
: 5
: Butane (G30) : 780 gr/hr.
Propane (G31) : 640 gr/hr.
: Butane (G30) : 37.0 mbar
Propane (G31) : 37.0 mbar
: 29.0 mbar(*)
: 29.0 mbar(**)
: 2.0 mbar(***)
+corner
: 1x Ø20.0
mm +
2x Ø5.0 mm
+corner
: 1x Ø20,0
mm +
2x Ø5.0 mm
: Mertik GV 60
: Centre Fire 561x130 mm
: no 95 (= 1x Ø0.95 mm)
: no 125 (= 1x Ø1.25 mm)
: SIT 0.145.019
: no 23 (SIT 0.977.150)
: 3/8" G / Ø12 mm
: Ø100 mm - Ø150 mm or
Ø130 mm - Ø200 mm
83

Advertisement

Table of Contents
loading

This manual is also suitable for:

View bell derby 3 lfVwbdy3 cfVwbdy3 lf

Table of Contents