1.6.3 Gas connection
Operation (gas regulator block (and receiver)) outside the appliance (in the operating
unit):
The gas connection is situated where the operating unit is built in near to the appliance.
Use only gas piping with a minimum diameter of 1/2" and a shut-off valve.
1.6.4 Operating unit
If the appliance is fi tted with an operating unit comprising gas control block and receiver,
this will be located, once it has been built in, at a maximum of 50 cm from the left or
right hand side of the appliance.
1.6.5 Convection package connections
When fi tting a convection package (= convection casing and convection set (1x or 2x)),
consideration should be given to the openings at approximately 1 meter above the
appliance for the warm air exiting grids.
1.7 POSITIONING THE APPLIANCE
Important: •
The fi replace is constructed on a suffi ciently solid fl oor that
can bear the weight of the appliance.
Ensure a free space of at least 1 cm between the bottom of
the appliance and the fl oor.
Ensure that the temperature of the fl oor under and in front of the
appliance can never rise above 85°C! Make use of a temperature
protection plate (of nonfl ammable material) on the fl oor if
necessary. Take care with a fl oor made of a fl ammable material.
Figure 15: A clearence of at least 1 cm must be maintained between
the bottom of the appliance and the fl oor.