SECTION 7 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
Table 7-15. Exxon Univis HVI 26 Specs
Specific Gravity
Pour Point
Flash Point
at 40° C
at 100° C
Viscosity Index
NOTE:
Mobil/Exxon recommends that this oil be checked on a
yearly basis for viscosity.
7-10
32.1
-76°F (-60°C)
217°F (103°C)
Viscosity
25.8 cSt
9.3 cSt
376

Critical Stability Weights

Table 7-16. Critical Stability Weights
Component
Battery
Counterweight (S)
Counterweight (SJ)
Tires
Platform and Console - 36 x 72
Platform and Console - 36 x 96
Platform and Console - Fall Arrest
lb
kg
66
30
1060 ± 42.4
481.8 ± 19.3
2700 ± 54
1227.3 ± 24.5
See Table 7-8, Tires
209
95
240
109
287
130
3121670