Warning
If the supply cord of this appliance is damaged, it must only
be replaced by a repair shop appointed by the manufacturer,
because special purpose tools are required.
The wires in this mains lead are coloured in accordance with
the following code:
green/yellow = earth
blue = neutral
As the colours of the wires in the mains lead of this appliance
may not correspond with the coloured markings identifiying
the terminals in your plug, proceed as follows:
The wire which is coloured green and yellow must be
connected to the terminal in the plug which is marked with
the letter E or by the earth symbol or coloured green or
green and yellow.
The wire which is coloured blue must be connected to
the terminal which is marked with the letter N or coloured
black.
The wire which is coloured brown must be connected to
the terminal which is marked with the letter L or coloured
brown.
Should the moulded plug have to be replaced, never re-use
the defective plug or attempt to plug it into a different 13 A
socket. This could result in an electric shock.
14

CORRECTION OF MALFUNCTIONS

MALFUNCTION
The unit will not start
No coating material emerges
from the nozzle
Coating material drips from the
nozzle
brown = live
CAUSE
No mains voltage
Nozzle clogged
Material volume setting too low
Paint container seal damaged
No pressure build-up in container
Container empty
Ventilation hose loose/damaged
Feed tube loose
Feed tube / feed tube filter clogged
Air vent on feed tube blocked
Diaphragm stuck
The diaphragm is positioned the
wrong way round.
Air cap, nozzle or needle soiled
Spray attachment incorrectly
assembled
Nozzle loose
Nozzle seal is missing or worn
Nozzle worn
Needle worn
Should it be necessary to exchange the fuse in the plug only
use fuses approved by ASTA in accordance with BS 1362.
Only 13 Amp fuses may be used.
To ensure that the fuse and fuse carrier are correctly
mounted please observe the provided markings or colour
coding in the plug.
After changing the fuse, always make sure that the fuse
carrier is correctly inserted. Without the fuse carrier, it is not
permissible to use the plug.
The correct fuses and fuse carriers are available from your
local electrical supplies stockist.
REMEDY
Check
Clean
Increase volume
Replace
Tighten container
Refill
Insert or replace
Insert
Clean or use another filter
Clean
Remove and clean (see section 13.2)
Position the diaphragm correctly (see section
13.2)
Clean
Assemble correctly (see section 12.1)
Tighten Union nut
Insert an intact nozzle seal
Change
Use new spray attachment