For Max. 50 Ka; Temperature Class And Conductor Cross Section - Cooper CEAG GHG 635 GHG 635 Operating Instructions Manual

Explosion-protected manual motor starters
Table of Contents

Advertisement

Available languages

Available languages

1.4
Maximum rating current for short-circuit back-up fuse for max. 50 kA, if I cc > I cs *
Short circuit protection and max. back-up fuse
Setting range
0.10 A
.........
0.16 A
0.16 A
.........
0.25 A
0.25 A
.........
0.40 A
0.40 A
.........
0.63 A
0.63 A
.........
1.00 A
1.00 A
.........
1.60 A
1.60 A
.........
2.50 A
2.50 A
.........
4.00 A
4.00 A
.........
6.30 A
6.30 A
.........
9.00 A
9.00 A
.........
12.50 A
12.50 A
.........
16.00 A
16.00 A
.........
20.00 A
20.00 A
.........
25.00 A
1.5
Maximum rating current for short-circuit back-up fuse for max. 100 kA, if I cc > I cs *
Short circuit protection and max. back-up fuse
Setting range
0.10 A
.........
0.16 A
0.16 A
.........
0.25 A
0.25 A
.........
0.40 A
0.40 A
.........
0.63 A
0.63 A
.........
1.00 A
1.00 A
.........
1.60 A
1.60 A
.........
2.50 A
2.50 A
.........
4.00 A
4.00 A
.........
6.30 A
6.30 A
.........
9.00 A
9.00 A
.........
12.50 A
12.50 A
.........
16.00 A
16.00 A
.........
20.00 A
20.00 A
.........
25.00 A
*
I cc = prospective short-circuit current at installation location
I cs = Rated short-circuit breaking capacity
1.6
Temperature class and conductor cross-section
Setting range
0.10 A
.........
1.60 A
1.60 A
.........
2.50 A
2.50 A
.........
4.00 A
4.00 A
.........
9.00 A
9.00 A
.........
12.50 A
12.50 A
.........
16.00 A
16.00 A
.........
20.00 A
20.00 A
.........
25.00 A
Manual motor starters up to 25A, GHG 635
240 V AC
400V AC
I cs
gL, gG
I cs
Short circuit proof
no back-up fuse required, up to I cc = 50 kA
240 V AC
400V AC
I cs
gL, gG
I cs
Short circuit proof
no back-up fuse required, up to I cc = 100 kA
75 kA
60 kA
55 kA
50 kA
Temperature class
T 6
T 6
T 6
T 6
T 6
T 6
T 5
T 5
500V AC
gL, gG
I cs
gL, gG
40 kA
50A
30 kA
80A
27 kA
80A
25 kA
100A
22 kA
100A
20 kA
125A
500V AC
gL, gG
I cs
gL, gG
60 kA
35 / 40A
40 kA
50A
30 kA
80A
80A
27 kA
80A
100A
25 kA
100A
100A
22 kA
100A
125A
20 kA
125A
Min. conductor cross-section
Input
0.75 mm²
1.00 mm²
1.00 mm²
1.50 mm²
2.50 mm²
2.50 mm²
2.50 mm²
4.00 mm²
Cooper Crouse-Hinds GmbH
690V AC
I cs
gL, gG
40 kA
25A
10 kA
40A
7 kA
40A
5 kA
50A
4.5 kA
50A
4 kA
50A
3.5 kA
50A
3 kA
50A
690V AC
I cs
gL, gG
40 kA
25A
10 kA
40A
7 kA
40A
5 kA
50A
4.5 kA
50A
4 kA
50A
3.5 kA
50A
3 kA
50A
Output
0.75 mm²
1.00 mm²
1.50 mm²
1.50 mm²
2.50 mm²
2.50 mm²
2.50 mm²
4.00 mm²
9 9 9 9 9

Advertisement

Table of Contents
loading

Table of Contents