8 I/O CONTROL INSTRUCTIONS
(3) Output conversion
In the output conversion, the following processing is performed for the integrated value (T2,
T3).
SUMPTN
0
1
ERROR
• When an operation error occurs
8 - 36
Condition
BW1
T2
HILMT
SUM1
BW1
Others
SUM1
BW1
T2
HILMT
SUM1
BW1
Others
SUM1
BW1, SUM1
remainder of T2 / HILMT
remainder of T2 / HILMT
T2
T2
HILMT
HILMT
T2
T2
MELSEC-Q
BW2, SUM2
BW2
T3
SUM2
T3
BW2
T3
SUM2
T3
BW2
0
SUM2
0
BW2
T3
SUM2
T3
Error code: 4100
8 - 36