SMA SB3.0-1SP-US-41 Installation Manual page 71

Hide thumbs Also See for SB3.0-1SP-US-41:
Table of Contents

Advertisement

SMA Solar Technology AG
Length x width x height of the packaging
Transport weight
Operating temperature range
Non-operating temperature range
Maximum permissible value for relative humid-
ity, non-condensing
Maximum operating altitude above mean sea
level (MSL)
Typical noise emission for SB3.0-1SP-US-41 /
SB3.8-1SP-US-41 / SB5.0-1SP-US-41 /
SB6.0-1SP-US-41
Typical noise emission for SB7.0-1SP-US-41 /
SB7.7-1SP-US-41
Power loss in night mode
Maximum data volume per inverter with Speed-
wire/Webconnect
Additional data volume when using the
Sunny Portal live interface
Topology
Cooling method for SB3.0-1SP-US-41 /
SB3.8-1SP-US-41 / SB5.0-1SP-US-41 /
SB6.0-1SP-US-41
Cooling method for SB7.0-1SP-US-41 /
SB7.7-1SP-US-41
Enclosure type rating in accordance with UL50
Protection class
Grid configurations
Approvals and national standards, as per
04/2018
Installation Manual
800 mm x 600 mm x 300 mm
(31.5 in x 23.6 in x 11.8 in)
29 kg (63.93 lbs)
-25°C to +60°C (-13°F to +140°F)
-40°C to +60°C (-40°F to +140°F)
95 %
3000 m (9843 ft)
39 dB(A)
45 dB(A)
<5 W
550 MB/month
600 kB/hour
Transformerless
Convection
Fans
NEMA 3R
1
208 V delta connection,
240 V delta connection,
208 V delta connection : 120 V wye
connection,
240 V : 120 V split-phase system
UL 1741, IEEE 1547
SBxx-1SP-US-41-IA-xx-10
10 Technical Data
71

Advertisement

Table of Contents
loading

Table of Contents