Sunny Boy 6.0-Us / 7.0-Us / 7.7-Us - SMA SB3.0-1SP-US-41 Installation Manual

Hide thumbs Also See for SB3.0-1SP-US-41:
Table of Contents

Advertisement

SMA Solar Technology AG
Efficiency
Maximum efficiency at
208 V, η
max
CEC efficiency at 208
V, η
CEC
Maximum efficiency at
240 V, η
max
CEC efficiency at 240
V, η
CEC

10.1.2 Sunny Boy 6.0-US / 7.0-US / 7.7-US

DC input
Maximum PV array
power
Maximum input voltage
MPP voltage range
Rated input voltage
Minimum input voltage
Initial input voltage
Maximum input current
per input
Maximum short-circuit
current per input
Maximum input source
reverse current to input
source
Number of indepen-
dent MPP inputs
AC output
Rated power at 208 V
Rated power at 240 V
Installation Manual
SB3.0-1SP-US-41
97.2 %
96 %
97.6 %
96.5 %
SB6.0-1SP-US-41
9600 Wp
600 V
100 V to 550 V
220 V to 480 V
100 V
125 V
10 A
18 A
0 A
3
SB6.0-1SP-US-41
5200 W
6000 W
SB3.8-1SP-US-41
97.2 %
96.5 %
97.5 %
96.5 %
SB7.0-1SP-US-41
11200 Wp
600 V
100 V to 550 V
245 V to 480 V
100 V
125 V
10 A
18 A
0 A
3
SB7.0-1SP-US-41
6650 W
7000 W
SBxx-1SP-US-41-IA-xx-10
10 Technical Data
SB5.0-1SP-US-41
97.2 %
96.5 %
97.5 %
97.0 %
SB7.7-1SP-US-41
12320 Wp
600 V
100 V to 550 V
270 V to 480 V
100 V
125 V
10 A
18 A
0 A
3
SB7.7-1SP-US-41
6650 W
7680 W
67

Advertisement

Table of Contents
loading

Table of Contents