Power Supply Modules - Supermicro SuperStorage 5049P-E1CR45L User Manual

Table of Contents

Advertisement

SuperStorageServer 5049P-E1CR45(L/H) User's Manual

Power Supply Modules

The chassis features redundant power supplies. The power modules can be changed without
powering down the system. New units can be ordered directly from Supermicro or authorized
distributors.
The power supplies are auto-switching capable. This feature enables them to automatically
sense the input voltage and operate at a 100-120v or 180-240v. An amber light will be
illuminated on the power supply when the power is off. An illuminated green light indicates
that the power supply is operating.
Replacing the Power Supply
1. Unplug the AC cord from the module to be replaced.
2. Push the release tab on the back of the power module as illustrated.
Release Tab
Figure 3-12. Replacing the Power Supply Module
3. Pull the power module out using the handle provided.
4. Push the new power module into the bay until it clicks into place.
5. Plug the AC power cord back into the module.