The information in this User's Manual has been carefully reviewed and is believed to be accurate. The vendor assumes
no responsibility for any inaccuracies that may be contained in this document, and makes no commitment to update
or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note:
For the most up-to-date version of this manual, please see our website at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual
at any time and without notice. This product, including software and documentation, is the property of Supermicro and/
or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except
as expressly permitted by the terms of said license.
IN NO EVENT WILL Super Micro Computer, Inc. BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT
OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPER
MICRO COMPUTER, INC. SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED
OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING,
INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
SuperServer
®
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the
State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution
5019S-MT
of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the manufacturer's instruction manual,
may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only
to products containing CR (Manganese Dioxide) Lithium coin cells. "Perchlorate Material-special handling may apply.
See www.dtsc.ca.gov/hazardouswaste/perchlorate".
WARNING: Handling of lead solder materials used in this product may expose you to lead, a
chemical known to the State of California to cause birth defects and other reproductive harm.
The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment,
nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical
systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic
property damage. Accordingly, Supermicro disclaims any and all liability, and should buyer use or sell such products
for use in such ultra-hazardous applications, it does so entirely at its own risk. Furthermore, buyer agrees to fully
indemnify, defend and hold Supermicro harmless for and against any and all claims, demands, actions, litigation, and
proceedings of any kind arising out of or related to such ultra-hazardous use or sale.
Manual Revision 1.0
Release Date: February 18, 2016
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this
document. Information in this document is subject to change without notice. Other products and companies referred
to herein are trademarks or registered trademarks of their respective companies or mark holders.
USER'S MANUAL
Copyright © 2016 by Super Micro Computer, Inc.
All rights reserved.
Revision 1.0
Printed in the United States of America
2

Advertisement

Table of Contents
loading

Summary of Contents for Supermicro SUPERSERVER 5019S-MT

  • Page 1 5019S-MT of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product. FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules.
  • Page 2: Table Of Contents

    This manual is written for professional system integrators and PC technicians. It provides 1.3 System Specifications ......................9 information for the installation and use of the SuperServer 5019S-MT. Installation and maintainance should be performed by experienced technicians only. 1.4 Server Chassis Features ....................10 Please refer to the 5019S-MT server specifications page on our website for updates on Control Panel ........................10...
  • Page 3 SuperServer 5019S-MT User's Manual Preface Processor and Heatsink Installation ..................25 Chapter 6 BIOS Memory Installation ......................30 6.1 Introduction .........................59 Memory Support ......................30 Starting the Setup Utility ....................59 DIMM Module Population Sequence ................31 6.2 Main Setup .........................60 DIMM Module Population Configuration ................31 6.3 Advanced Setup Configurations ..................62...
  • Page 4 SuperServer 5019S-MT User's Manual Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Website: www.supermicro.com Europe Address: Super Micro Computer B.V.
  • Page 5: Chapter 1 Introduction

    1.2 Unpacking the System Hard Drives Inspect the box the SuperServer 5019S-MT was shipped in and note if it was damaged in Four hot-swap SATA hard drives any way. If any equipment appears damaged, please file a damage claim with the carrier Power who delivered it.
  • Page 6: Server Chassis Features

    SuperServer 5019S-MT User's Manual Chapter 1: Introduction 1.4 Server Chassis Features Front Features The SC813MFTQC-350CB is a mini 1U chassis. See the illustration below for the features included on the front of the chassis. Control Panel The switches and LEDs located on the control panel are described below. See Chapter 4 for more details on the control panel.
  • Page 7: Rear Features

    SuperServer 5019S-MT User's Manual Chapter 1: Introduction Rear Features 1.5 Motherboard Layout The illustration below shows the features included on the rear of the chassis. Below is a layout of the X11SSH-TF with jumper, connector and LED locations shown. See the table on the following pages for descriptions.
  • Page 8: Quick Reference Table

    SuperServer 5019S-MT User's Manual Chapter 1: Introduction Quick Reference Table Jumper Description Default Setting Connector Description JBR1 BIOS Recovery Pins 1-2 (Normal) JSD1/JSD2 SATA DOM Power Connectors JBT1 CMOS Clear Open (Normal) JSTBY1 Standby Power Header C1/JI SMB to PCI-E Slots Enable/Disable...
  • Page 9 SuperServer 5019S-MT User's Manual IMVP 8 3 PHASE 2 PHASE for Vcore 80W #B-1 Available on the X11SSH-CTF #B-0 #A-1 #A-0 MINI SAS HD PCI-E X8 Gen3 LSI SAS3008 MINI SAS HD LGA1151 PCI-E X8 Gen3 SLOT6 PCIe3.0 x8 DMI3...
  • Page 10: Chapter 2 Server Installation

    SuperServer 5019S-MT User's Manual Chapter 2: Server Installation Chapter 2 • In single rack installations, stabilizers should be attached to the rack. In multiple rack in- stallations, the racks should be coupled together. • Always make sure the rack is stable before extending a server or other component from Server Installation the rack.
  • Page 11: Circuit Overloading

    SuperServer 5019S-MT User's Manual Chapter 2: Server Installation 2.3 Installing the Rails Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry There are a variety of rack units on the market, which may require a slightly different assembly and the effect that any possible overloading of circuits might have on overcurrent protection procedure.
  • Page 12: Installing The Rack Rails

    SuperServer 5019S-MT User's Manual Chapter 2: Server Installation 2.4 Installing the Server into a Rack You should now have rails attached to both the chassis and the rack. The next step is to install the server into the rack. 1. Line up the rear of the chassis rails with the front of the rack rails.
  • Page 13: Installing The Server Into A Telco Rack

    SuperServer 5019S-MT User's Manual Installing the Server into a Telco Rack To install the SuperServer 5019S-MT into a Telco (or “open”) type rack, use two L-shaped brackets on either side of the chassis (four total). 1. First, determine how far the server will extend out from the front of the rack. The chassis should be positioned so that the weight is balanced between front and back.
  • Page 14: Chapter 3 Maintenance And Component Installation

    4. Lift the cover from the chassis. • Refer to the Supermicro website for updates on CPU support. Installing the Processor(s) Begin by removing power from the system as described in Section 3.1. 1. Remove the cover plate that protects the CPU#1 socket: press the load lever to release...
  • Page 15 SuperServer 5019S-MT User's Manual Chapter 3: Maintenance and Component Installation Load Plate Load Lever Figure 3-4. Inspecting the Processor Installation Figure 3-2. Removing the Processor Cover Plate 5. With the processor inserted into the socket, inspect the four corners of the CPU to make sure that it is properly installed and flush with the socket.
  • Page 16 SuperServer 5019S-MT User's Manual Chapter 3: Maintenance and Component Installation 3. Add the two remaining screws then finish the installation by fully tightening all four 3. Once the heatsink is loose, remove it from the CPU. screws (be careful not to overtighten).
  • Page 17: Memory Installation

    DIMMB2 Total System Memory the memory slot. 16GB Release Tabs 16GB 32GB 16GB 16GB 32GB Figure 3-8. Installing DIMMs 16GB 16GB 16GB 16GB 64GB Note: Visit the product page on the Supermicro website for possible updates to memory support (www.supermicro.com).
  • Page 18: Pci Expansion Card Installation

    SuperServer 5019S-MT User's Manual Chapter 3: Maintenance and Component Installation PCI Expansion Card Installation 3.4 Chassis Components The system includes a pre-installed riser card (p/n CSE-RR1U-E8) that positions a standard size PCI-E x8 card at a 90 degree angle, allowing it to fit inside the chassis.
  • Page 19: Hard Drive Carrier Indicators

    Solid on Drive failure that the fan is working properly before replacing the chassis cover. Note: Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro website at http://www.
  • Page 20: Air Shroud

    Power Supply Failure If the power supply unit fails, the system will shut down and you will need to replace the unit. Replacement units can be ordered directly from Supermicro (see contact information in the Preface). Removing the Power Supply Begin by removing power from the system as described in Section 3.1.
  • Page 21 SuperServer 5019S-MT User's Manual Figure 3-14. Removing/Replacing a Power Supply...
  • Page 22: Chapter 4 Motherboard Connections

    Chapter 4: Motherboard Connections Chapter 4 Motherboard Connections This section describes the connections on the motherboard and provides pinout definitions. Note that depending on how the system is configured, not all connections are required. The LEDs on the motherboard are also described here. A severboard layout indicating component locations may be found in Appendix B.
  • Page 23: Headers And Connectors

    SuperServer 5019S-MT User's Manual Chapter 4: Motherboard Connections Secondary Power Connector SGPIO Headers JPWR2 must also be connected to the power supply. This connector is used to power the I-SGPIO1 and I-SGPIO2 (Serial General Purpose Input/Output) headers are used to processor(s).
  • Page 24 Note: UID can also be triggered via IPMI on the motherboard. For more information on IPMI, A System Management Bus header for IPMI 2.0 is located at JIPMB1. Connect a cable to please refer to the IPMI User's Guide posted on our website at http://www.supermicro.com. this header to use the IPMB I C connection on your system.
  • Page 25: Control Panel

    Note: UID can also be triggered via IPMI on the motherboard. For more information on IPMI, Ground please refer to the IPMI User's Guide posted on our website at http://www.supermicro.com. HDD LED The HDD LED connection is located on pins 13 and 14 of JF1. Attach a cable here to indicate...
  • Page 26: Data Cables

    SuperServer 5019S-MT User's Manual Chapter 4: Motherboard Connections Power Button Data Cables The Power Button connection is located on pins1 and 2 of JF1. Momentarily contacting both The data cables in the system have been carefully routed to maintain airflow efficiency. If pins will power on/off the system.
  • Page 27: Ports

    SuperServer 5019S-MT User's Manual Chapter 4: Motherboard Connections 4.3 Ports Universal Serial Bus (USB) Ports There is one USB 2.0 port (USB0/1) and one USB 3.0 port (USB6/7) located on the I/O back Serial Ports panel. The X11SSH-TF also has two front access USB 2.0 headers (USB2/3 and USB4/5) Two COM ports (COM1 &...
  • Page 28: Jumpers

    SuperServer 5019S-MT User's Manual Chapter 4: Motherboard Connections 4.4 Jumpers VGA Enable/Disable JPG1 allows you to enable or disable the VGA port using the onboard graphics controller. The default setting is Enabled. Explanation of Jumpers To modify the operation of the motherboard, jumpers are used to choose between optional VGA Enable/Disable settings.
  • Page 29: Led Indicators

    SuperServer 5019S-MT User's Manual Chapter 4: Motherboard Connections LANCONF Flash SMBus to PCI Slots Use the JPCK1 jumper to flash the LAN EEPROM. The default setting is Disabled. Jumpers JI C1 and JI C2 allow you to connect the System Management Bus (I C) to the PCI-E/PCI slots.
  • Page 30 SuperServer 5019S-MT User's Manual Onboard Power LED LEDPWR is an Onboard Power LED. When this LED is lit, it means power is present on the motherboard. In suspend mode, this LED will blink on and off. Be sure to turn off the system and unplug the power cord(s) before removing or installing components.
  • Page 31: Chapter 5 Software

    You must first configure RAID settings (if using RAID) before you install the Windows OS and the software drivers. To configure RAID settings, please refer to the RAID Configuration User Guides posted on our website at www.supermicro.com/support/manuals. Installing the Windows OS for a RAID System 1.
  • Page 32: Driver Installation

    The Supermicro FTP site contains drivers and utilities for your system at ftp://ftp.supermicro. The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based com. Some of these must be installed, such as the chipset driver. interface for Windows and Linux operating systems. The program monitors such system health...
  • Page 33: Ipmi

    SuperServer 5019S-MT User's Manual 5.4 IPMI The X11SSH-TF support the Inteliigent Platform Management Interface (IPMI). IPMI is used to provide remote access, monitoring and management. There are several BIOS settings that are related to IPMI. For general documentation and information on IPMI, please visit our website at:...
  • Page 34 Chapter 6: BIOS Chapter 6 BIOS 6.1 Introduction This chapter describes the AMIBIOS™ Setup utility for the X11SSH-CTF/TF motherboard. The BIOS is stored on a chip and can be easily upgraded using a flash program. Note: Due to periodic changes to the BIOS, some settings may have been added or deleted and might not yet be recorded in this manual.
  • Page 35 SuperServer 5019S-MT User's Manual Chapter 6: BIOS 6.2 Main Setup Memory Information Total Memory When you first enter the AMI BIOS setup utility, you will enter the Main setup screen. You can always return to the Main setup screen by selecting the Main tab on the top of the screen.
  • Page 36 SuperServer 5019S-MT User's Manual Chapter 6: BIOS 6.3 A dvanced Setup Configurations Wait For 'F1' If Error Use this feature to force the system to wait until the 'F1' key is pressed if an error occurs. Use the arrow keys to select Boot Setup and press <Enter> to access the submenu items.
  • Page 37 SuperServer 5019S-MT User's Manual Chapter 6: BIOS Active Processor Cores CPU Configuration This feature determines how many CPU cores will be activated for each CPU. When all The following CPU information will display: is selected, all cores in the CPU will be activated. (Please refer to Intel's website for more •...
  • Page 38 SuperServer 5019S-MT User's Manual Chapter 6: BIOS Package Power Limit MSR Lock C-State Auto Demotion Select Enabled to lock the package power limit for the model specific registers. The options Use this feature to prevent unnecessary excursions into the C-states to improve latency. The are Disabled and Enabled.
  • Page 39 SuperServer 5019S-MT User's Manual Chapter 6: BIOS Primary PEG Chipset Configuration This feature allows the user to select the primary PCI Express Graphics (PEG) slot. The Warning: Setting the wrong values in the following features may cause the system to malfunc- default is CPU SLOT6 PCI-E 3.0 X8 (IN X8).
  • Page 40 SuperServer 5019S-MT User's Manual Chapter 6: BIOS SAS3008 Max Payload Size Program PCIe ASPM After OPROM Select Auto for the system BIOS to automatically set the maximum payload value for the PCIe ASPM, the Active State Power Management for PCI Express slots, is a power PEG0 device to enhance system performance.
  • Page 41 SuperServer 5019S-MT User's Manual Chapter 6: BIOS Fast Boot PCH SLOT4 PCI-E 3.0 X2 (IN X4) Use this feature to enable or disable fast path through the memory reference code. The SLOT4 ASPM Support options are Enabled and Disabled. Use this item to set the Active State Power Management (ASPM) level for a PCI-E device.
  • Page 42 SuperServer 5019S-MT User's Manual Chapter 6: BIOS PCIe PLL SSC Port 0 ~ Port 7 SATA Device Type Use this item to specify if the SATA port specified by the user should be connected to a Solid Enable this feature to reduce EMI interference by down spreading clock 0.5%. Disable this feature to centralize the clock without spreading.
  • Page 43 SuperServer 5019S-MT User's Manual Chapter 6: BIOS Onboard 10G LAN Option ROM Type Serial Port 1 Use this item to select the Onboard 10G LAN Option ROM type. The options are Disabled, Select Enabled to enable the selected onboard serial port. The options are Disabled and Legacy, and EFI.
  • Page 44 SuperServer 5019S-MT User's Manual Chapter 6: BIOS • ME FW Status Value COM1 Data Bits Use this feature to set the data transmission size for Console Redirection. The options are • ME FW State 7 Bits and 8 Bits. •...
  • Page 45 SuperServer 5019S-MT User's Manual Chapter 6: BIOS COM1 Redirection After BIOS POST COM2 Stop Bits Use this feature to enable or disable legacy console redirection after BIOS POST. When set to A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial data Bootloader, legacy console redirection is disabled before booting the OS.
  • Page 46 SuperServer 5019S-MT User's Manual Chapter 6: BIOS EMS Console Redirection Settings WHEA Support Select Enabled to support the Windows Hardware Error Architecture (WHEA) platform and This feature allows the user to specify how the host computer will exchange data with the provide a common infrastructure for the system to handle hardware errors within the Windows client computer, which is the remote computer used by the user.
  • Page 47 SuperServer 5019S-MT User's Manual Chapter 6: BIOS Intel Ethernet Controller X550 - 00:25:90:5D:AF:26 Storage Hierarchy  Use this item to disable or enable storage hierarchy for cryptographic protection. The options are Disabled and Enabled. NIC Configuration Endorsement Hierarchy Link Speed Use this item to disable or enable endorsement hierarchy for privacy control. The options are This feature allows the user to specify the port speed used for the selected boot protocol.
  • Page 48 SuperServer 5019S-MT User's Manual Chapter 6: BIOS Virtual MAC Address Link Status This item displays the Virtual MAC address for this computer. Mac addresses are six two-digit This item displays the connection status. hexadecimal numbers. MAC Address Intel Ethernet Controller X550 - 00:25:90:5D:AF:27 This item displays the MAC address for this computer.
  • Page 49 SuperServer 5019S-MT User's Manual Chapter 6: BIOS 6.4 Event Logs SMBIOS Event Long Standard Settings Log System Boot Event Use this feature to configure Event Log settings. This option toggles the System Boot Event logging to enabled or disabled. The options are Disabled and Enabled.
  • Page 50 SuperServer 5019S-MT User's Manual Chapter 6: BIOS 6.5 IPMI When SEL is Full This feature allows the user to decide what the BIOS should do when the system event log Use this feature to configure Intelligent Platform Management Interface (IPMI) settings.
  • Page 51 SuperServer 5019S-MT User's Manual Chapter 6: BIOS 6.6 Security Station MAC Address This item displays the Station MAC address for this computer. Mac addresses are 6 two-digit This menu allows the user to configure the following security settings for the system.
  • Page 52 SuperServer 5019S-MT User's Manual Chapter 6: BIOS Secure Boot Mode Append Key Use this item to select the secure boot mode. The options are Standard and Custom. Select Yes to add the database from the manufacturer's defaults to the existing DB. Select No to load the DB from a file.
  • Page 53 SuperServer 5019S-MT User's Manual Chapter 6: BIOS 6.7 Boot • Legacy/UEFI/Dual/Boot Order #8 Use this feature to configure Boot Settings: • Legacy/UEFI/Dual/Boot Order #9 • Legacy/UEFI/Dual/Boot Order #10 • Legacy/UEFI/Dual/Boot Order #11 • Legacy/UEFI/Dual/Boot Order #12 • Legacy/UEFI/Dual/Boot Order #13 •...
  • Page 54 SuperServer 5019S-MT User's Manual Chapter 6: BIOS 6.8 Save & Exit Default Options Select the Exit tab from the BIOS setup utility screen to enter the Exit BIOS Setup screen. Restore Optimized Defaults To set this feature, select Restore Optimized Defaults from the Save & Exit menu and press <Enter>.
  • Page 55 When BIOS performs the Power On Self Test, it writes checkpoint codes to I/O port 0080h. If the computer cannot complete the boot process, a diagnostic card can be attached to the computer to read I/O port 0080h (Supermicro p/n AOC-LPC80-20). A-1 BIOS Error Beep (POST) Codes For information on AMI updates, please refer to http://www.ami.com/products/.
  • Page 56 Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes de Read this appendix in its entirety before installing or configuring components in the Supermicro manipular cualquier equipo, considere los riesgos de la corriente eléctrica y familiarícese chassis.
  • Page 57 SuperServer 5019S-MT User's Manual Appendix B: Standardized Warning Statements Warnung ‫جسذٌة‬ ‫اصابة‬ ً‫تتسبب ف‬ ‫حالة ٌوكي أى‬ ً‫اًك ف‬ ‫خطز‬ ًٌ‫ٌع‬ ‫هذا الزهز‬ !‫تحذٌز‬ Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ‫الذوائز‬ ‫بالوخاطز الٌاجوة عي‬ ‫ي على علن‬...
  • Page 58 SuperServer 5019S-MT User's Manual Appendix B: Standardized Warning Statements Power Disconnection Warning Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Warning! The system must be disconnected from all sources of power and the power Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung cord removed from the power supply module(s) before accessing the chassis interior nicht mehr als: 250 V, 20 A beträgt.
  • Page 59 SuperServer 5019S-MT User's Manual Appendix B: Standardized Warning Statements Attention ‫امداد‬ ‫وحدة‬ ‫من‬ ‫سهك انكهرباء‬ ‫وإزانت‬ ‫انطاقت‬ ‫مصادر‬ ‫من جميع‬ ‫اننظاو‬ ‫يجب فصم‬ Il est vivement recommandé de confier l'installation, le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés.
  • Page 60 SuperServer 5019S-MT User's Manual Appendix B: Standardized Warning Statements Battery Handling Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen. Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und Schlüssel oder einer Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace sonstigen Sicherheitsvorkehrung möglich.
  • Page 61 SuperServer 5019S-MT User's Manual Appendix B: Standardized Warning Statements ¡Advertencia! ‫فعليل‬ ‫بطريقة غير صحيحة‬ ‫البطارية‬ ‫انفجار في حالة اسحبذال‬ ‫من‬ ‫هناك خطر‬ Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para cortar ‫اسحبذال البطارية‬ por completo el suministro de energía, deben desconectarse todas las conexiones.
  • Page 62 SuperServer 5019S-MT User's Manual Appendix B: Standardized Warning Statements Backplane Voltage ‫اللىحة‬ ‫أوالطاقة المىجىدة على‬ ‫التيار الكهزبائي‬ ‫مه‬ ‫خطز‬ ‫هناك‬ ‫هذا الجهاس‬ ‫خدمة‬ ‫كه حذرا عند‬ ‫يعمل‬ ‫النظام‬ ‫عندما يكىن‬ Warning! Hazardous voltage or energy is present on the backplane when the system is operating.
  • Page 63 SuperServer 5019S-MT User's Manual Appendix B: Standardized Warning Statements ‫תיאום חוקי החשמל הארצי‬ Attention !‫אזהרה‬ La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou ‫הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬...
  • Page 64 섀시로부터 팬 조립품을 제거할 때 팬은 여전히 회전하고 있을 수 있습니다. 팬 조림품 Verwendung von UL-oder CSA-zertifizierte Kabel, UL oder CSA auf der Code für alle anderen 외관의 열려있는 부분들로부터 손가락 및 스크류드라이버, 다른 물체들이 가까이 하지 elektrischen Geräte als Produkte von Supermicro nur bezeichnet gezeigt haben. 않도록 배치해 주십시오. Waarschuwing ¡Advertencia!
  • Page 65 Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand. Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of CSA gecertificeerde kabels die UL of CSA die op de code voor andere elektrische apparaten dan de producten die door Supermicro alleen.
  • Page 66 Appendix C: System Specifications Appendix C System Specifications Processors Single 6th Gen Core 3, Xeon E3-1200 v5, Pentium and Celeron processors in an LGA 1151 (H4) type socket Note: Please refer to the motherboard specifications pages on our website for updates to supported processors. Chipset Intel C236 chipset BIOS...
  • Page 67 SuperServer 5019S-MT User's Manual Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/3-3, CISPR 22 Class A Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)

Table of Contents