BLOWER PERFORMANCE DATA - MODEL BDP
Table 17.1 - Models With or Without Blower Enclosure - Blower Model BDP j k
0.5" Static Press.
Model
ATR
CFM
Size
RPM
HP
40
2778
750
1
45
2469
715
50
2222
685
3/4
150
55
2020
665
60
1852
650
65
1709
640
1/2
70
1587
630
40
3241
970
2
45
2881
900
1-1/2
50
2593
845
1
175
55
2357
805
60
2160
770
3/4
65
1994
745
70
1852
725
1/2
40
3704
615
1-1/2
45
3292
590
1
50
2963
570
200
55
2694
555
3/4
60
2469
545
65
2279
540
70
2116
535
1/2
40
4630
750
2
45
4115
695
1-1/2
50
3704
660
250
55
3367
630
1
60
3086
605
65
2849
590
3/4
70
2646
575
40
5556
-
-
45
4938
865
3
50
4444
805
2
300
55
4040
760
60
3704
720
1/2
65
3419
690
70
3175
660
1
40
6481
1070
5
45
5761
975
50
5185
905
3
350
55
4714
845
60
4321
800
2
65
3989
760
1-1/2
70
3704
725
40
-
-
-
45
6584
1010
5
50
5926
935
400
55
5387
870
3
60
4938
820
65
4558
780
2
70
4233
745
1-1/2
Data for use with filters only
0.6" Static Press.
Drive Turns RPM
HP
Drive Turns RPM
1 .5
-
-
2 .0
755
1
38
2 .5
730
3 .0
715
38
3/4
700
1 .5
96
690
2 .0
680
1/2
96
80
2 .5
1005
2
80
193
1 .0
935
1-1/2
193
2 .5
885
3 .0
845
1
192
815
3 .5
192
790
3/4
96
0 .0
770
105
4 .0
650
1-1/2
105
1 .0
625
610
1 .5
1
16
595
590
16
2 .0
585
3/4
101
0 .5
580
108
2 .5
775
2
108
2 .0
725
105
3 .0
690
1-1/2
105
665
2 .0
645
205
1
205
2 .5
630
3 .0
615
3/4
-
-
-
-
111
2 .0
890
3
111
108
1 .0
830
2
108
2 .5
785
106
3 .5
750
1-1/2
106
4 .0
720
205
1 .0
695
1
205
0 .5
1095
207
5
207
2 .0
1000
1 .0
930
111
3
111
2 .5
870
210
3 .5
825
2
210
0 .0
790
100
105
1-1/2
1 .0
755
105
-
-
-
-
-
1 .5
1035
207
5
207
3 .0
955
2 .0
895
111
3
111
3 .0
850
210
4 .0
805
2
210
105
0 .5
775
0.7" Static Press.
HP
Drive Turns
-
-
-
-
-
1 .5
-
-
-
-
-
-
-
-
2 .0
-
-
-
-
-
-
-
-
2 .5
-
-
-
-
1 .0
-
-
-
-
1 .5
1035
1 .0
2
80
0 .5
970
2 .5
1 .5
920
1-1/2
193
0 .5
880
1 .5
2 .5
1
855
2 .0
192
3 .0
830
3/4
2 .5
3 .5
815
3 .0
-
-
-
-
4 .0
-
-
-
-
-
-
-
-
0 .5
-
-
-
-
-
-
-
-
1 .0
-
-
-
-
-
-
-
-
2 .0
-
-
-
-
3 .0
755
2
108
2 .5
2 .0
720
1 .0
1-1/2
105
3 .0
695
2 .0
0 .5
680
1
205
1 .0
665
2 .0
655
-
-
-
-
-
1 .5
915
1 .0
3
111
0 .5
860
2 .0
1 .5
815
2
108
1 .0
2 .5
780
1 .5
3 .5
750
1-1/2
106
2 .5
0 .5
725
3 .0
0 .0
-
-
-
-
1 .5
1025
5
207
1 .5
0 .5
955
0 .0
3
111
2 .0
900
1 .0
3 .0
855
2 .5
2
210
4 .0
815
3 .0
0 .0
785
1-1/2
100
4 .0
-
-
-
-
1 .0
1055
0 .5
5
207
2 .5
980
2 .0
1 .0
920
0 .5
3
111
2 .5
875
2 .0
3 .5
835
2 .5
2
210
4 .0
800
3 .5
6-189.18
Filters
For blower units with enclosure and filter, add the
following static pressures to the static pressure
determined by the system designer for total external
static pressure .
BDP 150
0 .1" W .C .
BDP 175
0 .2" W .C .
BDP 200
0 .1" W .C .
BDP 250
0 .2" W .C .
BDP 300
0 .2" W .C .
BDP 350
0 .2" W .C .
BDP 400
0 .2" W .C .
Alternate Drives for 208-230/460V
HP & Drive
HP & Drive
Model
Listed
Needed
150
1 - 38
=
1 - 254
1 - 192
=
1 - 256
175
1-1/2 - 193
=
1-1/2 - 198
1-1/2 - 79
=
1-1/2 - 80
1 - 16
=
1 - 178
1-1/2 - 105
=
1-1/2 - 180
200
1-1/2 - 23
=
1-1/2 - 177
1 - 205
=
1 - 157
1-1/2 - 105
=
1-1/2 - 180
250
1-1/2 - 23
=
1-1/2 - 177
1 - 205
=
1 - 157
300
1-1/2 - 105
=
1-1/2 - 180
1-1/2 - 23
=
1-1/2 - 177
1 - 205
=
1 - 157
1-1/2 - 106
=
1-1/2 - 108
350
1-1/2 - 105
=
1-1/2 - 180
400
1-1/2 - 105
=
1-1/2 - 180
Alternate Drives for 575V
Drive for
Drive for
Model
Under 575V
1/4 - 191
=
1/4 - 197
1/3 - 191
=
1/3 - 197
150
1/3 - 95
=
1/3 - 96
1 - 38
=
1 - 254
1/3 - 95
=
1/3 - 96
1 - 192
=
1 - 256
175
1-1/2 - 193
=
1-1/2 - 198
1/4 - 212
=
1/4 - 213
1/3 - 212
=
1/3 - 213
200
1/3 - 102
=
1/3 - 101
1 - 16
=
1 - 178
1-1/2 - 105
=
1-1/2 - 180
1/3 - 203
=
1/3 - 204
250
1 - 205
=
1 - 157
1-1/2 - 105
=
1-1/2 - 180
1 - 205
=
1 - 157
1-1/2 - 106
=
1-1/2 - 108
300
1-1/2 - 105
=
1-1/2 - 180
1 - 205
=
1 - 157
350
1-1/2 - 105
=
1-1/2 - 180
1-1/2 - 100
=
1-1/2 - 210
400
1-1/2 - 105
=
1-1/2 - 180
j Outputs shown are for elevations up to 2000' . For elevations
over 2000', output needs to be reduced 4% for each 1000'
above sea level . (Does not apply in Canada - see rating plate)
k Sheave turns open are approximate . For proper operation,
check blower rpm
l Models not shown use same HP and drive numbers as
cataloged
m Performance is the same; motor sheave
accommodates larger shaft . When ordering 230/460V (1 &
1-1/2 HP) or 575V, specify the listed 230/460V (1 & 1-1/2 HP)
or 575V drive .
l
l
575V
17