Modine Manufacturing HD Series Installation And Service Manual

Modine Manufacturing HD Series Installation And Service Manual

Gas-fired unit heaters
Hide thumbs Also See for HD Series:
Table of Contents
  • Table of Contents
  • Inspection À L'arrivée
  • Précautions Spéciales
  • Facteurs de Conversion Métrique (SI)
  • Avant de Commencer
  • Emplacement D'installation
    • Matières Combustibles Et Dégagements
    • Montage de L'appareil
    • Installation de L'appareil
    • Ventilation
    • Raccordements Au Gaz
    • Ensemble D'accessoires Pour Haute Altitude
    • Électriques
    • Câblage Et Réglage de la Vitesse de la Soufflante
  • Mode D'emploi
  • Éléments Constitutifs
  • Dimensions
  • Maintenance/Dépannage
  • Schéma de Câblage de L'appareil
  • Numéro de Série Ou de Modèle Et Pièces de Rechange
  • Garantie Commerciale

Advertisement

Available languages

Available languages

WARNING
1. Improper installation, adjustment, alteration,
service, or maintenance can cause property
damage, injury, or death, and could cause exposure
to substances which have been determined by
various state agencies to cause cancer, birth
defects, or other reproductive harm. Read the
installation, operating, and maintenance instructions
thoroughly before installing or servicing this
equipment.
2. Do not locate ANY gas-fired units in areas where
chlorinated, halogenated, or acid vapors are
present in the atmosphere. These substances can
cause premature heat exchanger failure due to
corrosion, which can cause property damage,
serious injury, or death.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS:
1. Open windows.
2. Do not try to light any appliance.
3. Do not touch any electrical switch; do
not use any phone in your building.
4. Immediately call your gas supplier
from a neighbor's phone. Follow the gas
supplier's instructions. If you can not reach
your gas supplier, call your fire department.
FOR YOUR SAFETY
The use and storage of gasoline or other flammable
vapors and liquids in open containers in the vicinity
of this appliance is hazardous.
PLEASE BE SURE TO LEAVE IT WITH THE OWNER WHEN YOU LEAVE THE JOB.
INSTALLATION AND SERVICE MANUAL
THIS MANUAL IS THE PROPERTY OF THE OWNER.
gas-fired unit heaters
model HD and HDB
All models approved for use in California by the CEC and
in Massachusetts. Unit heater is certified for residential and
commercial applications. These unit heaters are certifed as Utility
heaters and are intended for the heating of non-living spaces that
are attached to, adjacent to, or part of a structure that contains
space for family living quarters. They are not intended to be the
primary source of heat in residential applications.
IMPORTANT
The use of this manual is specifically intended
for a qualified installation and service agency. All
installation and service of these units must be
performed by a qualified installation and service
agency.
Inspection on Arrival
1. Inspect unit upon arrival. In case of damage, report it
immediately to the transportation company and your local
Modine sales representative.
2. Check rating plate on unit to verify that power supply meets
available electric power at the point of installation.
3. Inspect unit upon arrival for conformance with description of
product ordered (including specifications where applicable).
Table of Contents
Inspection on Arrival . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Special Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SI (Metric) Conversion Factors. . . . . . . . . . . . . . . . . . . . . . . . . 3
Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Unit Location. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Combustible Material and Service Clearances . . . . . . . . . 4
Unit Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Unit Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Venting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Gas Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
High-Altitude Accessory Kit . . . . . . . . . . . . . . . . . . . . . . . 13
Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Wiring/Blower Speed Adjustment . . . . . . . . . . . . . . . . . . 16
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Unit Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Service/Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Unit Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Model/Serial Number/Replacement Parts . . . . . . . . . . . . . . . 22
Commercial Warranty. . . . . . . . . . . . . . . . . . . . . . . . Back Cover
6-583.12
5H0800040000
October, 2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Modine Manufacturing HD Series

  • Page 1 6-583.12 5H0800040000 October, 2019 INSTALLATION AND SERVICE MANUAL gas-fired unit heaters model HD and HDB All models approved for use in California by the CEC and in Massachusetts. Unit heater is certified for residential and commercial applications. These unit heaters are certifed as Utility heaters and are intended for the heating of non-living spaces that WARNING are attached to, adjacent to, or part of a structure that contains...
  • Page 2 SPECIAL PRECAUTIONS SPECIAL PRECAUTIONS CAUTION THE INSTALLATION AND MAINTENANCE INSTRUCTIONS IN THIS MANUAL MUST BE FOLLOWED TO PROVIDE SAFE, EFFICIENT, AND TROUBLE-FREE OPERATION. IN ADDITION, PARTICULAR CARE 1. All literature shipped with this unit should be kept for MUST BE EXERCISED REGARDING THE SPECIAL PRECAUTIONS future use for servicing or service diagnostics.
  • Page 3 SPECIAL PRECAUTIONS / SI (METRIC) CONVERSION FACTORS BEFORE YOU BEGIN CAUTION CAUTION 17. When leak testing the gas supply piping system, the appliance and its combination gas control must be isolated 1. All literature shipped with this unit should be kept for future during any pressure testing in excess of 14"...
  • Page 4 UNIT LOCATION UNIT LOCATION DANGER Table 4.1 Clearances Clearance to Combustible Recommended Service Unit Side Material Clearance Appliances must not be installed where they may be exposed HD/HDB to a potentially explosive or flammable atmosphere. Top and Bottom 1" 6" 18"...
  • Page 5 UNIT MOUNTING Figure 5.2 - Unit Heater Turned 180° CAUTION (30-75 units only) (Access panel and heated air outlet change sides) 1. Do not install units below 7' measured from the bottom of the unit to the floor in commercial applications (unless unit is properly guarded to provide user protection from moving parts) and 5' measured from the bottom of the unit to the floor in residential applications.
  • Page 6 INSTALLATION - VENTING WARNING Table 6.1 - Vent Pipe Diameters and Total Equivalent Vent Pipe Lengths For Horizontal Venting Systems 1. Gas fired heating equipment must be vented - do not Minimum Maximum Model Size Vent Pipe Diameter Eqv. Length Eqv.
  • Page 7 INSTALLATION - VENTING diameter is necessary. If there is 6' or more of vent pipe in A18. In addition to following these general instructions, specific the open space between the appliance and where the vent instructions for Vertical Category I or Horizontal Category III pipe passes through the wall or floor, the thimble need only vent systems must also be followed.
  • Page 8 INSTALLATION - VENTING Figure 8.1 - Vertical Vent Termination for Double Section B – Vertical Vent System Installation Wall Vent Pipe and Greater Than or Less Than 8’ B1. This section applies to vertically vented Category I Horizontally From a Vertical Wall or Obstruction vent systems and is in addition to “Section A –...
  • Page 9 INSTALLATION - VENTING • For single wall vent pipe and 10' or greater horizontal • For single wall vent pipe and less than 10' horizontal distance distance to any portion of a building, the vent must terminate at to any portion of a building, the vent must terminate 2' higher least 3' (2' for non-residential installations) above the highest than any portion of that building (see Figure 9.2).
  • Page 10 INSTALLATION - VENTING Section C – Horizontal, Category III Vent System C6. The venting system must be exclusive to a single unit, and Installation no other unit is allowed to be vented into it. C1. This section applies to horizontally vented Category III Figure 10.2 - Horizontal Category III Venting with vent systems and is in addition to “Section A –...
  • Page 11 INSTALLATION - VENTING Additional Requirements for Common Venting: Table 11.1 - Maximum Vent Connector Horizontal Run (ft) - Type B Vent Connector 1. The common vent system and all attached appliances must be Category I. Connector 2. The vent connector should be routed in the most direct Model Max Horiz.
  • Page 12 INSTALLATION - GAS CONNECTIONS Figure 12.1 - Recommended Sediment Trap/Manual WARNING Shut-off Valve Installation - Side or Bottom Gas Connection 1. All field gas piping must be pressure/leak tested prior to operation. Never use an open flame. Use a soap solution or equivalent for testing.
  • Page 13 INSTALLATION - HIGH ALTITUDE ACCESSORY KIT HIGH ALTITUDE ACCESSORY KIT Manifold Pressure Adjustment The inlet pressure to the unit must be confirmed to be within Modine’s gas-fired equipment standard input ratings are acceptable limits (6-7" W.C. for natural gas and 11-14" W.C. certified by ETL.
  • Page 14 INSTALLATION - HIGH ALTITUDE ACCESSORY KIT If the heating value of the gas being supplied is different than the values shown in Tables 13.1 and 13.2, use the following equation to determine the appropriate manifold pressure for the altitude and gas heating value being supplied. Equation 14.1 - Manifold Pressure for Derated Gas WHERE: = Manifold Pressure (in.
  • Page 15 INSTALLATION - ELECTRICAL CONNECTIONS ELECTRICAL CONNECTIONS W ARNING 1. Disconnect power supply before making wiring connections to prevent electrical shock and equipment damage. 2. All appliances must be wired strictly in accordance with wiring diagram furnished with the appliance. Any wiring different from the wiring diagram could result in a hazard to persons and property.
  • Page 16 INSTALLATION - ELECTRICAL CONNECTIONS ELECTRICAL CONNECTIONS Blower Curve Models (HDB 60-125 Only) Location of thermostat should be determined by heating Speeds requirements and be mounted on an inside wall about 5' above floor level where it will not be affected by heat from the unit Medium High or other sources, or drafts from frequently opened doors.
  • Page 17 INSTALLATION - OPERATION OPERATION 10. Turn on power to the unit at the disconnect switch. 11. Check the thermostat, ignition control, gas valve, and supply Prior to Operation fan blower motor for electrical operation. If these do not IMPORTANT function, check that the wiring is per the diagram. 12.
  • Page 18 CONTROL OPERATING SEQUENCE / UNIT COMPONENTS CONTROL OPERATING SEQUENCE Upon a call for heat from the thermostat, power is supplied to all ready started it will start shortly. If a flame is not sensed for the power exhauster motor. The unit will go through a purge any reason the main valve will close and there will be a short period and then the direct spark igniter will be energized.
  • Page 19 DIMENSIONAL DATA - MODEL HD/HDB Propeller Units - Model HD Blower Units - Model HDB Figure 19.2 Dimensional Drawings - Model HDB Figure 19.1 Dimensional Drawings - Model HD 14.9" BETWEEN 3/8"-16 MOUNTING HOLES 14.9" BETWEEN 3/8"-16 MOUNTING HOLES (MODEL SIZES 100 AND 125 ONLY) MOUNTING HOLES TYP (MODEL SIZES 100 AND 125 ONLY) 3/8 x 1"...
  • Page 20 SERVICE / MAINTENANCE / TROUBLESHOOTING 1. Service air moving components annually. WARNING a. Check fan for fit on motor shaft and for damage to blades. 2. Keep unit free from dust, dirt, grease, and foreign matter, When servicing or repairing this equipment, use only factory- paying particular attention to: approved service replacement parts.
  • Page 21 UNIT WIRING Wiring Diagram Selection Since internal or factory wiring may vary depending on type. The following wiring diagram represents a unit equipped the controls manufacturer, the wiring diagrams must be with a single or two stage gas valve and direct spark ignition. appropriately selected with the proper gas valve and ignition Figure 21.1 - Unit Heater Wiring Diagram (Single and Two Stage, Direct Spark Ignition) GR, (G)
  • Page 22 MODEL & SERIAL NUMBER / REPLACEMENT PARTS Figure 22.1 - Model Number Designations (Remove access cover to locate) HD - Tubular Power Vented Factory Installed Option Digit Propeller Unit N - None HDB - Tubular Power Vented Blower Unit Future A - All MBH Input 30 - 30,000 Btu/hr input...
  • Page 23 THIS PAGE INTENTIONALLY LEFT BLANK 6-583.12...
  • Page 24 Burners High Intensity Infrared Units Sheet Metal Parts All Products As Modine Manufacturing Company has a continuous product improvement program, it reserves the right to change design and specifications without notice. Modine Manufacturing Company 1500 DeKoven Avenue Racine, WI 53403 Phone: 1.800.828.4328 (HEAT)
  • Page 25: Table Of Contents

    6-583.12 5H0800040000 Octobre, 2019 MANUEL D'INSTALLATION ET DE MAINTENANCE appareils de chauffage au gaz modèles HD et HDB Tous les modèles approuvés pour une utilisation en Californie par le CEC et au Massachusetts. L'appareil de chauffage est certifié pour des applications résidentielles et commerciales.
  • Page 26: Précautions Spéciales

    PRÉCAUTIONS PARTICULIÈRES PRÉCAUTIONS PARTICULIÈRES ATTENTION LES INSTRUCTIONS D'INSTALLATION ET D'ENTRETIEN DE CE MANUEL DOIVENT ÊTRE RESPECTÉES POUR ASSURER UN FONCTIONNEMENT SÉCURITAIRE, EFFICACE ET SANS PROBLÈMES. IL CONVIENT ÉGALEMENT 1. Toute la documentation livrée avec l'appareil doit être conservée pour DE RESPECTER RIGOUREUSEMENT LES PRÉCAUTIONS PARTICULIÈRES référence lors des opérations d'entretien et de diagnostic des pannes.
  • Page 27: Facteurs De Conversion Métrique (Si)

    PRÉCAUTIONS PARTICULIÈRES / FACTEURS DE CONVERSION SI (SYSTÈME MÉTRIQUE) / EMPLACEMENT D'INSTALLATION AVANT DE COMMENCER ATTENTION ATTENTION 17. Pour l'essai d'étanchéité des tuyauteries d'alimentation en gaz, l'appareil et son régulateur de gaz combiné doivent être isolés pour 1. Toute la documentation livrée avec l'appareil doit être conservée pour tout essai fait à...
  • Page 28: Emplacement D'installation

    EMPLACEMENT D'INSTALLATION EMPLACEMENT D'INSTALLATION Tableau 4.1 Dégagements DANGER Dégagement Distance minimum recommandé pour la Côté appareil des matières combustibles Les appareils ne doivent pas être installés à un endroit où ils risquent maintenance d'être exposés à une atmosphère potentiellement explosive ou HD/HDB inflammable.
  • Page 29: Montage De L'appareil

    MONTAGE DE L'APPAREIL Figure 5.2 - Appareil tourné de 180° (modèles 30-75 seulement) ATTENTION (Panneau d'accès et sortie d'air réchauffé changent de côté) 1. Dans le cas d'applications commerciales, les appareils ne doivent pas être installés à une hauteur de moins de 2,1 m (7 pi), mesurée entre le dessous et le plancher (à...
  • Page 30 INSTALLATION – ÉVACUATION AVERTISSEMENT Tableau 6.1 - Diamètres de tuyau d'évacuation et longueurs de tuyau d'évacuation équivalentes totales pour les systèmes d'évacuation horizontaux 1. Un système d'évacuation est obligatoire pour les appareils de Taille de Diamètre de Équiv. Équiv. chauffage au gaz – ne les faites jamais fonctionner sans évacuation modèle conduit minimum Longueur...
  • Page 31: Ventilation

    INSTALLATION – ÉVACUATION entre l'appareil et la traversée du mur ou du plancher a une longueur A18. En plus de ces instructions générales, il convient d'observer les supérieure à 1,8 m (6 pi), le manchon peut avoir un diamètre de 5 instructions particulières données pour les systèmes d'évacuation cm (2 po) seulement de plus que le tuyau.
  • Page 32 INSTALLATION – ÉVACUATION Figure 8.1 - Sortie verticale de conduit à double paroi Section B – Installation des systèmes d'évacuation verticale débouchant à plus ou moins de 2,4 m (8 pieds) horizontalement B1. Cette section s'applique aux systèmes d'évacuation verticale de d'un mur ou d'un obstacle vertical catégorie I et complète les prescriptions de la section A –...
  • Page 33 INSTALLATION – ÉVACUATION • Pour les conduits à simple paroi débouchant à une distance • Pour des conduits d'évacuation à simple paroi débouchant à moins de horizontale de 3 m (10 pi) ou plus d'une partie quelconque d'un bâtiment, 3 m (10 pi) horizontalement de toute partie du bâtiment, le conduit doit se le conduit doit se prolonger sur au moins 0,9 m (3 pi) –...
  • Page 34 INSTALLATION – ÉVACUATION Section C – Installation des systèmes d'évacuation horizontale C5. Si la condensation risque d'être un problème, le système d'évacuation ne doit pas déboucher au-dessus d'une voie publique ou d'une de catégorie III. zone où le condensat ou la vapeur pourrait créer une nuisance ou C1.
  • Page 35 INSTALLATION – ÉVACUATION Exigences additionnelles relativement à l'évacuation commune : Tableau 11.1 - Longueur horizontale maximale de conduit de raccordement (pi) – type B 1. Le système d'évacuation commune et tous les appareils connexes doivent être de catégorie I. Diam. connecteur Modèle Long.
  • Page 36: Raccordements Au Gaz

    INSTALLATION – RACCORDEMENTS DE GAZ Figure 12.1 - Installation recommandée : piège à sédiments et AVERTISSEMENT robinet d'arrêt manuel – Pour un raccordement latéral ou par le bas 1. Toutes les tuyauteries de gaz extérieures doivent être soumises à ARRIVÉE DE GAZ des essais de pression et d'étanchéité...
  • Page 37: Ensemble D'accessoires Pour Haute Altitude

    INSTALLATION – ENSEMBLE D'ACCESSOIRES POUR HAUTE ALTITUDE ENSEMBLE D'ACCESSOIRES POUR HAUTE ALTITUDE Régler de pression au collecteur La pression d'arrivée dans l'appareil doit être confirmée dans les limites Les valeurs nominales d'entrée standard des appareils au gaz de Modine acceptables (6 à 7 po C.E. pour le gaz naturel et 11 à 14 po C.E. pour le sont certifiés par ETL.
  • Page 38 INSTALLATION – ENSEMBLE D'ACCESSOIRES POUR HAUTE ALTITUDE Si la valeur de chauffage du gaz fourni est différente des valeurs des tableaux 13.1 et 13.2, utilisez l'équation suivante pour déterminer la pression appropriée au collecteur pour l'altitude et la valeur de chauffage du gaz fourni.
  • Page 39: Électriques

    RACCORDEMENTS ÉLECTRIQUES AVERTISSEMENT 1. Débranchez l'alimentation avant d'effectuer des branchements pour éviter tout risque d'électrocution et d'endommagement de l'appareil. 2. Tous les branchements et câblages doivent être faits en stricte conformité avec le schéma fourni avec l'appareil. Tout câblage différent de celui du schéma peut créer des risques de dommages matériels ou de blessures.
  • Page 40: Câblage Et Réglage De La Vitesse De La Soufflante

    INSTALLATION – BRANCHEMENTS ÉLECTRIQUES Modèles de courbes de soufflantes RACCORDEMENTS ÉLECTRIQUES (HDB 60-125 seulement) Le thermostat de commande sera installé en fonction des besoins Vitesses dechauffage, sur une cloison intérieure à environ 1,5 m (5 pi) au-dessus du plancher et de façon à ne pas être exposé à la chaleur de l'appareil Basse Moyenne Haute...
  • Page 41: Mode D'emploi

    INSTALLATION – FONCTIONNEMENT FONCTIONNEMENT 11. Vérifiez le thermostat, l'allumeur, le robinet de gaz, puis mettez la soufflante sous tension. Si le fonctionnement n'est pas normal, vérifiez Avant la mise en service si le câblage est conforme au schéma. IMPORTANT 12. Vérifiez que le moteur de la soufflante tourne dans le bon sens en comparant avec la flèche marquée sur le corps (s'il y a lieu).
  • Page 42: Éléments Constitutifs

    SÉQUENCE FONCTIONNELLE DE SYSTÈME DE COMMANDE SÉQUENCE FONCTIONNELLE DE SYSTÈME DE COMMANDE Lorsque le thermostat détecte une demande de chaleur, le moteur de la il démarrera peu après. Si une flamme n'est pas détectée (pour une raison soufflante d'extraction démarre. L'appareil effectue un cycle de purge avant quelconque), la soupape principale se referme et l'appareil effectue un bref que l'allumeur direct par étincelle soit mis sous tension.
  • Page 43: Dimensions

    DIMENSIONS – MODÈLE HD/HDB Modèle à hélice – Modèle HD Modèles à soufflante – Modèle HDB Figure 19.1 - Plans cotés – Modèle HD Figure 19.2 - Plans cotés – Modèle HDB 14.9 PO ENTRE LE 3/8"-16 TROUS DE MONTAGE 14.9 PO ENTRE LE 3/8"-16 TROUS DE MONTAGE TROUS DE FIXATION (MODÈLE TAILLE 100 ET 125 SEULEMENT)
  • Page 44: Maintenance/Dépannage

    ENTRETIEN – MAINTENANCE – DÉPANNAGE AVERTISSEMENT 1. Entretien annuel des composants de transport de l'air. a. Vérifiez que l'hélice du ventilateur est bien fixée sur l'arbre du moteur et que ses pales ne sont pas endommagées. 2. L'appareil doit être nettoyé de toute accumulation de poussière, saleté, Pour l'entretien et les réparations de cet appareil, n'utiliser que des graisse et matières étrangères, avec une attention particulière portée pièces d'origine certifiées.
  • Page 45: Schéma De Câblage De L'appareil

    CÂBLAGE DE L'APPAREIL Choix du schéma de câblage Le câblage interne ou posé en usine et le câblage dépend du modèle Le schéma suivant est celui d'un appareil équipé d'un régulateur à un ou à de contrôleur installé et il est important de choisir les schémas qui deux étages, avec allumage direct à...
  • Page 46: Numéro De Série Ou De Modèle Et Pièces De Rechange

    NUMÉRO DE SÉRIE ET DE MODÈLE ET PIÈCES DE RECHANGE Figure 22.1 - Composition du numéro de modèle (ouvrir le panneau d'accès) HD - Appareil tubulaire à Chiffre d'option installée à l'usine soufflante motorisée N - Aucun HDB - Appareil tubulaire à hélice motorisée Futur A - Tous...
  • Page 47 PAGE VIERGE 6-583.12...
  • Page 48: Garantie Commerciale

    Modèles infrarouges de haute intensité Pièces en tôle Tous les produits Comme la Modine Manufacturing Company a un programme d'amélioration permanente de ses produits, elle se réserve le droit de modifier la conception et les caractéristiques techniques sans préavis. Modine Manufacturing Company...

Table of Contents

Save PDF