PERFORMANCE, UTILITIES AND CLEARANCE - MODEL IPT

Table 10.1 - Performance
Input MBH
Certified Tube Lengths (ft.)
Recommended
Mounting Height (ft.)
Spot or Area
Recommended
Heating
Tube System
Total Building
Application
Heating
➀ Recommended Mounting Height and Tube System Applications are meant as a general guide and are adjusted to meet the requirements of the actual application.
The applications are as follows:
-- Spot or Area Heating is an application where occupant comfort is the goal and occupant(s) are either relatively stationary (Spot - Example: small work cell or
dispersed over a slightly wilder range than with Spot Heating (Area - Example: assembly line). Mounting height is typically at the low end of the range shown above.
-- Total Building Heating is an application where average space temperature is to be maintained, however due to the significant temperature gradient differences
on long straight tube systems, areas may exist where direct occupant comfort is not achieved.
➁ IPT 100 not available for Propane Gas operation at 50 ft. tube system length.
➂ IPT 75 not available for Propane Gas operation at 40 ft. tube section length.
Table 10.2 - Utilities
Electrical Rating
Gas Connection (inch)
60Hz/1Ph
1/2 NPT
Table 10.3 - Combustible Material
Clearances
➀ ➁ ➂
IPT
Combustible Material Clearances (inches)
1
Input MBH
"A"
"B"
50/60
9
75/100/125
9
150/175/200
12
➀ Clearance to each end and above the U-Tube is 12 inches.
➁ In unvented applications, clearance from radiant tube end
is 36" in all directions.
➂ Refer to Figures 8.1 through 8.3.
Figure 10.2 - Stacking Height
Minimum Clearance to
Combustible Materials
Mounting
Stacking
Height
Height
50
60
20, 30
20, 30, 40 20, 30, 40
10 – 12
10 – 12
12 – 14
Minimum Gas Inlet
Pressure
(" W.C.)
7.0 (natural gas)
11.0 (propane gas)
2
3
"C"
54
20
76
24
106
38
75
100
125
30, 40,
40, 50, 60
50
12 – 14
15 – 22
U-Tube
Straight Tube
Maximum Gas
Inlet Pressure
Manifold Gas Pressure (' W.C.)
("W.C.)
3.5 (natural gas-single stage)
2.5 (natural gas-two stage)
14.0
10.0 (propane gas-single stage)
6.2 (propane gas-two stage)
Figure 10.1 - Combustible Material Clearances -
Straight Tube
"A"
"C"
"C"
0° MOUNTING ANGLE
Figure 8.3 - Combustible Material Clearances - U-Tube
0° MOUNTING ANGLE
CHAIN LOCATION
"A"
CHAIN LOCATION
"A"
"C"
"C"
"B"
"B"
"U" TUBE
"U" TUBE
0° MOUNTING ANGLE
0° MOUNTING ANGLE
9-123.5
150
175
200
50, 60,
50, 60,
50, 60
70
70
15 – 22
18 – 28
20 - 30
Tube/Vent Diameter
CHAIN LOCATION
"A"
CHAIN LOCATION
"A"
"A"
"C"
"C"
"B"
"C"
45° MOUNTING ANGLE
"C"
(MAXIMUM)
"B"
"B"
CHAIN LOCATION
45° MOUNTING ANGLE
(MAXIMUM)
"A"
CHAIN LOCATION
"A"
"A"
"A"
"C"
"C"
"B"
"C"
"B"
"B"
"C"
45° MOUNTING ANGLE
(inch)
4 (O.D.)
"B"
"B"
12"
"B"
12"
"B"
"U" TUBE
"U" TUBE
45° MOUNTING ANGLE
(MAXIMUM)
(MAXIMUM)
11