Chapter 5 Display And Setting Of Various Functions; List Of Function - SMC Networks HRS-R Series Operation Manual

Thermo chiller
Table of Contents

Advertisement

Chapter 5
Read and understand this manual carefully before changing the
settings.

5.1 List of function

NO
Function
1
Main display
2
Alarm display menu
Inspection monitor
3
menu
4
Key-lock
Timer for operation
5
start/stop
Signal for the
6
completion of
preparation
7
Offset function
Reset after power
8
failure
9
Anti-freezing function
Key click sound
10
setting
11
Changing temp. unit
Changing pressure
12
unit
Setting of alarm
13
buzzer
14
Alarm customizing
15
Data reset
Accumulation time
16
reset
17
Communication
Option J
18
[Automatic water-fill
port ]
HRS-R Series
Display and setting of
various functions
The product can have the displays and settings shown in table 5-1.
Table 5-1 List of function
Displays the current temperature of the circulating fluid, discharge
pressure of the circulating fluidhange the circulating fluid temperature.
Indicates alarm number when an alarm occurs.
Product temperature, pressure and accumulated operating time can be
checked as daily inspection. Use these for daily inspection.
Keys can be locked so that set values cannot be changed by operator
error.
Timer is used to set the operation start/stop.
A signal is output when the circulating fluid temperature reaches the set
temperature, when using contact input/output and serial communication.
Use this function when there is a temperature offset between the
discharge temperature of the thermo-chiller and the customer's device.
Start operation automatically after the power supply is turned on.
Circulating fluid is protected from freezing during winter time or night time.
Set beforehand if there is a risk of freezing.
Operation panel key sound can be set on/off.
Temperature unit can be changed.
o
Centigrade (
C)⇔Fahrenheit (
Pressure unit can be changed.
MPa⇔ PSI
Alarm sound can be set to on/off.
Operation during alarm condition and threshold values can be changed
depending on the alarm type.
Functions can be reset to the default settings (settings when shipped from
the factory).
Reset function when the pump, the fan, or the compressor is replaced.
Accumulated time is reset.
This function is used for contact input/output or serial communication.
This function is available for customer who selected option [Automatic
fluid filling] (Refer to P2-1 Name and Function of Parts)
Chapter 5
Display and setting of various functions
Outline
o
F)
HRX-OM-X027
Reference
page
5.3
5.4
5.5
5.6
5.7
5.8
5.9
5.10
5.11
5.12
5.13
5.14
5.15
5.16
5.17
5.18
5.19
6.1
5.1 List of function