BR-Automation X20CP1301 Manual page 7

Table of Contents

Advertisement

Model number
Pulse width modulation
12)
Period duration
Pulse duration
Resolution for pulse duration
Diagnostic status
Leakage current when switched off
R
DS(on)
Residual voltage
Peak short-circuit current
Switching on after overload or short-
circuit cutoff
Switching delay
0 → 1
1 → 0
Switching frequency
Resistive load
14)
Inductive load
Braking voltage when switching off in-
ductive loads
Electrical properties
Electrical isolation
Operating conditions
Mounting orientation
Horizontal
Vertical
Installation elevation above sea level
0 to 2000 m
>2000 m
Degree of protection per EN 60529
Ambient conditions
Temperature
Operation
Horizontal mounting orientation
Vertical mounting orientation
Derating
Storage
Transport
Relative humidity
Operation
Storage
Transport
Mechanical properties
Note
Dimensions
Width
Height
Depth
Weight
1)
The specified values are maximum values. For examples of the exact calculation, see section "Mechanical and electrical configuration" of the X20 system
user's manual.
2)
When operated in parallel, the nominal power of 2 W is not permitted to be added to the total power.
3)
Up to 2 W bus load.
4)
The size of the memory used for remanent variables is configurable in Automation Studio.
5)
See Automation Help under "Communication / POWERLINK / General information / Hardware - IF/LS" for more information.
6)
Based on the current measured value.
7)
Based on the 20 V measurement range.
8)
Based on the 20 mA measurement range.
9)
Based on the current resistance value.
10)
Based on the entire resistance measurement range.
11)
For the high-speed digital outputs, derating must be taken into account at a switching frequency >50 kHz (see section "Derating for switching frequency of
high-speed digital outputs"). Overtemperature protection is not provided.
Data sheet V1.21
X20CP1301
Standard outputs and mixed channels: Output monitoring with 10 ms delay
High-speed outputs: Output monitoring with 10 µs delay
Standard outputs and mixed channels: <0.1 V at nominal current 0.5 A
High-speed outputs: <0.9 V at nominal current 0.1 A
Standard outputs and mixed channels: Approx. 10 ms (depends on module temperature)
Standard outputs and mixed channels: Max. 500 Hz
High-speed outputs: 50 kHz, max. 200 kHz (see section "Switching frequency derating for high-speed digital outputs")
Standard outputs and mixed channels: Typ. 45 VDC
Ethernet (IF2) and X2X (IF6) isolated from
each other, from other interfaces and from PLC
Channel isolated from bus
Channel not isolated from channel or PLC
Reduction of ambient temperature by 0.5°C per 100 m
See section "Switching frequency derating for high-speed digital outputs".
5 to 95%, non-condensing
Up to 100%, condensing
3 X20 terminal blocks (16-pin) included in delivery
300 g
Table 3: Technical data
X20(c)CP1301, X20CP1381 and X20CP1382
X20cCP1301
X20CP1381
5 to 65535 µs corresponds to 200 kHz to 15 Hz
0 to 100%, minimum 2.5 µs
0.1% of the configured frequency
Standard outputs and mixed channels: 5 µA
High-speed outputs: 25 µA
140 mΩ
13)
Standard outputs and mixed channels: <3 A
High-speed outputs: <20 A
High-speed outputs: No switch-on
Standard outputs and mixed channels: <300 µs
High-speed outputs: <3 µs
Standard outputs and mixed channels: <300 µs
High-speed outputs: <3 µs
See section "Switching inductive loads"
Ethernet (IF2), POWERLINK (IF3) and X2X (IF6) isolat-
ed from each other, from other interfaces and from PLC
Channel not isolated from channel or PLC
Yes
Yes
No limitation
IP20
-25 to 60°C
-25 to 50°C
-40 to 85°C
-40 to 85°C
5 to 95%, non-condensing
5 to 95%, non-condensing
X20 end cover plate (right) included in delivery
Interface module slot cover included in delivery
164 mm
99 mm
75 mm
X20CP1382
Channel isolated from bus
5 to 95%, non-condensing
310 g
7