12.2 Functions of the high-speed digital outputs
Possible functions
The high-speed digital outputs DO 9 to DO 12 can be configured for the following functions:
Channel
Function
DO 9
PWM - Pulse width modulation
DO 10
PWM - Pulse width modulation
DO 11
PWM - Pulse width modulation
DO 12
PWM - Pulse width modulation
Table 8: Possible functions of the high-speed digital inputs DO 9 to DO 12
Examples of possible configurations
Channel
Configuration 1
DO 9
PWM - Pulse width modulation
DO 10
PWM - Pulse width modulation
DO 11
D - Direction
DO 12
F - Frequency
Data sheet V1.21
Configuration 2
D - Direction
F - Frequency
PWM - Pulse width modulation
PWM - Pulse width modulation
X20(c)CP1301, X20CP1381 and X20CP1382
D - Direction
F - Frequency
D - Direction
F - Frequency
Configuration 3
PWM - Pulse width modulation
PWM - Pulse width modulation
PWM - Pulse width modulation
PWM - Pulse width modulation
Configuration 4
D - Direction
F - Frequency
D - Direction
F - Frequency