Indoor unit installation

9.1
Step 1: Select installation
location
1.1 Ensure the installation complies with
the installation minimum dimensions
(defined below) and meets the minimum
and maximum connecting piping length and
maximum change in elevation as defined in
the System Requirements section.
1.2 Air inlet and outlet will be clear of
obstructions, ensuring proper airflow
throughout the room.
1.3 Condensate can be easily and safely drained.
1.4 All connections can be easily made to
outdoor unit.
1.5 Indoor unit is out of reach of children.
1.6 A mounting wall strong enough to withstand
four times the full weight and vibration of
the unit.
Minimum indoor clearances
≥ 13cm/5 in.
Split type air conditioner / User Manual
1.7 Filter can be easily accessed for cleaning.
1.8 Leave enough free space to allow access for
1.9 Install at least 10 ft. (3 m) away from the
1.10 Do not install in a laundry room or by
1.11 For ETL certification area, Caution: Mount
Ceiling
≥ 20cm/8 in.
≥ 250cm/8ft.
Floor
routine maintenance.
antenna of TV set or radio. Operation of the
air conditioner may interfere with radio or TV
reception in areas where reception is weak.
An amplifier may be required for the affected
device.
a swimming pool due to the corrosive
environment.
with the lowest moving parts at least
8 ft. (2.4 m) above floor or grade level.
≥ 13cm/5 in.
39 / 120 EN