Installation Of The Indoor Unit - Beko BFYTI 360 Installation Manual

Floor standing air conditioner
Table of Contents

Advertisement

Available languages

Available languages

12
Installation manual
Installation diagram
Should be less
than 15m
Elbow to prevent
water from
entering room
The purchaser must ensure that the person
and/or company who is to install, maintain or
repair this air conditioner has qualifications and
experience in refrigerant products.
12.2 Installation of the
indoor unit
Before starting installation, decide on the
position of the indoor and outdoor units, taking
into account the minimum space reserved
around the units.
Warning:
Do not install your air
A
conditioner in a wet room
such as a bathroom or
laundry etc.
Note: The shape of the mounting
C
plate may be different from
the one above, but installation
method is similar.
Floor standing air conditioner / Installation Manual
Outdoor unit
Indoor
unit
Indoor unit
Should be less
than 15m
12.2.1 Drilling a hole in the wall
for the piping
1. Decide where to drill the hole in the wall for
the piping (if necessary) according to the
position of the indoor unit;
2. Install a flexible flange through the hole in the
wall to keep the latter intact and clean.
Indoors
Warning:
A
The hole must slope
downwards towards the
exterior.
Note: Keep the drain pipe down
C
towards the direction of the wall
hole, otherwise leakage may
occur.
Outdoor unit
Outdoors
5 mm
35 / EN