Instructions For Servicing (R32) - Beko BBVHO 090 User Manual

Table of Contents

Advertisement

6

Instructions for servicing (R32)

1. Check the information in this manual to find
out the dimensions of space needed for
proper installation of the device, including the
minimum distances allowed compared to
adjacent structures.
2. Appliance shall be installed, operated and
stored in a room with a floor area larger than
4 m
.
2
3. The installation of pipe-work shall be kept to
a minimum.
4. The pipe-work shall be protected from
physical damage, and shall not be installed in
an unventilated space if the space is smaller
than 4 m
.
2
5. The compliance with national gas regulations
shall be observed.
6. The mechanical connections shall be
accessible for maintenance purposes.
7. Follow the instructions given in this manual
for handling, installing, cleaning, maintaining
and disposing of the refrigerant.
8. Make sure ventilation openings clear of
obstruction.
9.
Note:
C
shall be performed only
as recommended by the
manufacturer.
10.
Warning:
shall be stored in a well-
A
ventilated area where the
room size corresponds to the
room area as specified for
operation.
Split type air conditioner / User Manual
The servicing
The appliance
11.
Warning:
shall be stored in a room
without continuously
A
operating open flames
(for example an operating
gas appliance) and ignition
sources (for example an
operating electric heater).
12. The appliance shall be stored so as to prevent
mechanical damage from occurring.
13. It is appropriate that anyone who is called
upon to work on a refrigerant circuit should
hold a valid and up-to-date certificate from
an assessment authority accredited by the
industry and recognizing their competence
to handle refrigerants, in accordance with
the assessment specification recognized
in the industrial sector concerned. Service
operations should only be carried out in
accordance with the recommendations of
the equipment manufacturer Maintenance
and repair operations that require the
assistance of other qualified persons must
be conducted under the supervision of the
person competent for the use of flammable
refrigerants.
14. Every working procedure that affects safety
means shall only be carried out by competent
persons.
The appliance
27 / 120 EN

Advertisement

Chapters

Table of Contents
loading