Test operation

11.2 Test run instruction

1. Turn on the power supply
2. Press the ON/OFF button on the remote
controller to turn on the air conditioner
3. Press the Mode button to switch the mode
COOL and HEAT.
In each mode set as below:
COOL-Set the lowest temperature
HEAT-Set the highest temperature
4. Run about 8 minutes in each mode and check
all functions are properly run and respond
the remote controller. Functions check as
recommended:
4.1 If the outlet air temperature respond the
cool and heat mode
4.2 If the water drains properly from the
drainage hose
4.3 If the Louver and deflectors(optional)
rota. properly
5. Observe the test run state of the air
conditioner at least 30 minutes.
6. After the successfully test run, return the
normal setting and press ON/OFF button on
the remote controller to turn off the unit.
7. Inform the user to read this manual carefully
before use, and demonstrate to the user
how to use the air conditioner, the necessary
knowledge for service and maintenance, and
the reminder for storage of accessories.
Note:
If the ambient temperature is
excess the range refer to section
C
Operation instructions, and it can
not run COOL or HEAT mode, lift
the front panel and refer to the
emergency button operation to
run the COOL and HEAT mode.