Test Dosing Module 0 986 610; Beaker Set 0 986 610; Scale 0 986 610 - Bosch Denoxtronic 2.1 Product Description

Test device adblue supply module
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
en
24 | Denoxtronic 2.1 | Devices and components
3.9

Test dosing module 0 986 610 464

The test dosing module (fig. 9, item 2) is used during
the function test of the AdBlue delivery module to
test the metered amount. The test dosing module is
controlled by the control unit in the delivery module
via the test adapter 0 986 610 180. The test liquid that
flows through the test dosing module is collected in a
beaker.
!
Defective test dosing modules may not be reused
and must be completely replaced.
Fig. 9:
Test dosing module and beaker
1 Beaker from beaker set 0 986 610 460
2 Test dosing module 0 986 610 464 placed on beaker
i
Detailed instructions on use and handling can be
found in the separate ESI[tronic] repair instructions
Denoxtronic 2.1.
3.10
Beaker set 0 986 610 460
The beaker set consists of 3 beakers with capacities
of 100 ml, 250 ml and 500 ml. It is used during the
function test of the AdBlue supply module to measure
return flow and the metered amount. The collected test
liquid is measured using the scale 0 986 610 838. See
examples of use in fig. 9 and fig. 10.
i
Only the entire beaker set can be replaced.
i
Detailed instructions on use and handling can be
found in the separate ESI[tronic] repair instructions
Denoxtronic 2.1.
|
1 689 989 404
2019-03-01
3.11
Scale 0 986 610 838
The scale is used during the function test of the AdBlue
supply module to measure return flow and the metered
amount. The amount collected in a beaker from the
beaker set 0 986 610 460 is weighed on the scale to
evaluate the target values.
i
The weight 0 986 610 839 must be used to calibrate
the scale (see section 3.12).
i
If the scale is defective, it must be replaced.
Fig. 10:
Scale 0 986 610 838
1 Scale (0 – 500 g)
2 Beaker from beaker set 0 986 610 460
i
Detailed instructions on use and handling can be
found in the separate ESI[tronic] repair instructions
Denoxtronic 2.1.