POWER AND CONTR O L WIR IN G
Power and control are arranged as separate bare-tail inputs via cords that are each 6.5' (2m)
in length.
POWER
The power feed is as follows. The fixture must have a valid ground connection:
• Voltage:
100-277VAC 50/60Hz
• Power:
60W
• Feed cable:
16 AWG / 1.31mm
Note: Acclaim recommends taking proper precautions for external surge protection, as control
and power electronics can be damaged by major events.
CONTRO L
The control cable has two cores for the 0-10V input:
• Feed cable:
18 AWG / 0.824mm
INPUT W IRING PR OTE C TIO N
Ensure that appropriate care is taken to protect the junction where the mains and control
inputs are joined to the fixture's feed cables.
Ensure that:
• the mains input is derived from a suitable overload-protected supply.
• the junction boxes have an environmental rating of at least IP66.
• all cable access points, plus the enclosure cover are correctly sealed and moisture proof.
• only suitable cable connectors are used within the junction boxes; Acclaim Lighting
recommends Wago® 221-series splicing connectors.
• local codes are followed during planning and installation. Some municipalities have
specific requirements when wiring low and high voltage cables in close proximity. Such
requirements could include the use of a barrier within combined junction boxes (if used)
or particular minimum spacings between the control and power cables.
• connections are made, inspected and certified by a qualified electrician.
8
Brown: Live
Green/yellow: Earth
Blue: Neutral
2
White: 0-10V +
Black: 0-10V -
2
www.acclaimlighting.com