Supermicro SuperServer SSG-631E-E1CR16H User Manual page 59

Table of Contents

Advertisement

Information LED (OH/Fan Fail/PWR Fail/UID LED)
The Information LED (OH/Fan Fail/PWR Fail/UID LED) connection is located on pins 7 and
8 of JF1. The LED on pin 7 is active when the UID button (JUIDB1) on the rear I/O panel
is pressed. The LED on pin 8 provides warnings of overheat, power failure, or fan failure.
Information LED-Blue+ (OH/Fan Fail/PWR Fail LED for LED5/blue UID LED) (Pin 7 & Pin 8 of JF1)
Status
Solid red (on)
Blinking red (1Hz)
Blinking red (0.25Hz)
Blinking red (10Hz) (FP red LED)
Solid blue
Blinking blue (1Hz)
BIOS/BMC blinking blue (10Hz)
Red Info LED blinking (10Hz) and
MB UID LED blue blinking (10Hz)
NIC1/NIC2 (LAN1/LAN2)
The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins 11
and 12 of JF1, and LAN port 2 is on pins 9 and 10.
LAN1/LAN2 LED
Pin Definitions (JF1)
Pin# Definition
9
NIC 2 Activity LED
11
NIC 1 Activity LED
ID_UID Switch/HDD LED
The UID Switch/HDD LED connection is located on pins 13 and 14 of JF1. The UID switch
is used for a chassis that supports a front UID switch. The front UID switch functions in the
same way as the rear UID switch; both are for input only and cannot be used for output.
When this LED is blinking green, it indicates HDD is active. Attach a cable to pins 13 and 14
to show ID_UID status and storage drive activity.
ID_UID/HDD LED
Pin Definitions (JF1)
Pins
Definition
13
ID_UID/3.3V Stdby
14
HDD Activity
LED Indicator Status
Description
An overheat condition has occurred.
Fan failure: check for an inoperative fan.
Power failure: check for a non-operational power supply
CPLD recovery mode error(s)
Local UID is activated. Use this function to locate a unit in a rack mount
environment that might be in need of service.
Remote UID is on. Use this function to identify a unit from a remote location that
might be in need of service.
BIOS/BMC: recovery and/or update in progress
CPLD: recovery and/or update in progress
Pin#
Definitin
10
NIC 2 Link LED
12
NIC 1 Link LED
59
Chapter 4: Motherboard Connections
LAN1/LAN2 LED
LED Indicator Status
Color
State
NIC 2: Blinking green
LAN 2: Active
NIC 1: Blinking green
LAN 1: Active
ID_UID/HDD LED
Pin Definitions (JF1)
Color
State
Blinking Green
HDD Active

Advertisement

Table of Contents
loading

This manual is also suitable for:

Superserver ssg-631e-e1cr16l

Table of Contents