DISCONNECT THE SCROLL SAW
FROM THE MAINS BEFORE
CONTINUING!
Checking & Replacing the Motor Brushes
After a period of time the scroll saws motor brushes are due
to wear and may need replacing, please follow the instruction
below for checking and replacing the brushes.
1. There are two motor brush ports one on either side of the
motor assembly, using a small flat head screwdriver remove
one of the motor's brush access plugs and place safely aside,
see fig 36-37-38.
Fig 36-37-38
Motor brush
access port
Remove the
access plug
NOTE: Be careful when removing the plug, the motor brush
is sprung loaded.
Remove the
motor brush
NOTE: Take careful note of the orientation of the brushes
when you remove them, remember that they have bedded
themselves to the profile of the commutator in that
position. If you fit them reversed they may not be in exactly
the same position, which can cause excessive sparking and
heat until they have re-bedded themselves.
2. Carefully remove the motor brush, see fig 39. Check the brush
for signs of wear. If it's O.K. re-fit. If the brush has worn down to
a theard of its length replace with a new one.
3. Turn the scroll saw on its side allowing access to the other
brush access port, see fig 40-41.
General Maintenance
The motor is permanently lubricated. Do not try to oil the motor
bearings or service any internal parts of the motor. If the power
cord is worn, frayed, cut or damaged, contact Axminster Tools
& Machinery. Do not try to patch it up with electrical tape, this
could lead to more trouble.
17

MAINTENANCE

Fig 39
Fig 41-42
Motor access port
Continues over...