9.2 Maintenance of the slide rod

Fig. 12: Maintenance of the slide rod
1
Rectangular O-ring
2
Sleeve
3
Holes for installation tool
4
O-ring
5
Slide rod
5
WARNING!
Danger from hazardous substances!
Possible consequence: Fatal or very serious inju‐
ries.
Please ensure when handling hazardous sub‐
stances that you have read the latest safety data
sheets provided by the manufacture of the haz‐
ardous substance. The actions required are
described in the safety data sheet. Check the
safety data sheet regularly and replace, if neces‐
sary, as the hazard potential of a substance can be
re-evaluated at any time based on new findings.
The system operator is responsible for ensuring
that these safety data sheets are available and that
they are kept up to date, as well as for producing
an associated hazard assessment for the worksta‐
tions affected.
1.
Close all compressed air and feed chemical shut-off valves.
2.
Bleed the compressed air lines.
3.
Disconnect the pump from the compressed air supply and all
supply and discharge lines.
Maintenance of the double diaphragm pump
1
2
3
4
A2732
27